SHARP LC-121M2E - SHARP LC-150M2E LCD AV MONITOR How to Disassemble – Adjustment modes - SCHEMATIC

How to Disassemble SHARP LC-121M2E - SHARP LC-150M2E LCD AV MONITOR– Adjustment Modes _ Circuit Diagram
AC adapter: UADP-0181CEZZ
DC power supply: 12 ± 0.5V
After initialization of E2PROM the mode is changed to the adjustment mode.
Procedure:  Connect TP2007 and TP2008 to GND, and turn on the power.
The initialization of microcomputer is as follows.
AV position, DAC data, G/A data, and video chroma data adjustment values are taken as defaults.
Change to adjustment mode
* Short-circuit TP2007 to GND, and turn on the power.
** Or short-circuit TP2008 to GND, and turn on the power.
** Or holding down the [AV INPUT] key and [MENU] key, turn on the main power, and simultaneously press the (inspection process) [SELECT ] key and [VOL– ] key to change the mode to the adjustment mode.
The manual adjustment or adjustment through communication with the automatic machine is performed.
Inspection mode
Holding down the [AV INPUT] key and [MENU] key, turn on the power.
* In the ordinary menu select “PICTURE” with the [SELECT] key, and decide with the [VOL] key. Then select “CONTRAST”, “TINT (only NTSC)”, “COLOR”, “BLACK LEVEL”, “SHARPNESS”, “RED” , and “BLUE” with the [SELECT] key, and decide with the [VOL] key. After that, adjust values with the [VOL] key.
* In the ordinary menu select “SOUND” with the [SELECT] key, and decide with the [VOL] key. Then, select “TREBLE”, “BASS”, and “BALANCE” with the [SELECT] key, and decide with the [VOL] key. After that adjust values with the [VOL] key.
* VOLUME, CONTRAST, TINT (only NTSC), COLOR, BLACK LEVEL, SHARPNESS, RED, BLUE, TREBLE, BASS, and BALANCE change sequentially.
Shipping setting mode
Holding down the [AV INPUT] key and [MENU] key, turn on the main power, and simultaneously press the (inspection process) [SELECT] key and [VOL+] key to change the mode to the adjustment mode.
User adjustment and other values are taken as defaults.
If AV1 is indicated as SETTING COMPLETE, setting has been completed.
To Cancel (Exit) the  special mode
Turn off the main unit power.
DISASSEMBLY
1. Remove four screws (1).
2. Opening six claws ( a ), release the cabinet B.  Remove the wire holder ( b ) and disconnect each connectors (2~6).  Remove the cabinet B.
3. Remove two screws (7) which mounting the LCD display unit.
4. Remove soldering of copper-foil tape (8) .
5. Disconnect each connectors (9~e) from the LCD display unit.
6. Remove the cabinet A
7. Remove four screws (14) which mounting the main PWB unit.
8. Remove one screw (15) and remove the remote control receptor PWB.
9. Remove five screws (16) and GND cable.
10.Remove ten screws (17) and remove the terminal cover.
11.Remove two screws (18) and remove the switch PWB.
12. Remove one screw (19) and remove the Sosu shield angle.
13. Remove four screws (20) which mounting the LCD display unit.
14. Spread bites of the LCD unit (21) out to be off from claws.
15. Remove the Lamp unit (22).
SCHEMATICS
Click on the pictures to Magnify