POWER AMP & P/S _ SCHEMATIC
CLICK ON THE PICTURES TO ZOOM IN
ALIGNMENT
PROCEDURES
INITIAL
ADJUSTMENT (No load connected) {A. OUTPUT OFFSET VOLT AGE}
- Connect a DC Millivoltmeter to L Channel speaker output terminals.
- Turn unit ON and adjust VR21 (100 ohms) to get the reading of 0V+/-30mV.
- Connect the DC Millivoltmeter to R Channel speaker output terminals and adjust VR11 (100ohms) to get a reading of 0V+/-30mV.
- Connect a DC Millivoltmeter to TP1 and TP2 and adjust VR22 (300 ohms) for 3-5mV reading on meter.
- Connect the DC Millivoltmeter to TP3 and TP4 and adjust VR12 (300 ohms) for 3-5mV reading on meter.
- Leave power on for a minimum of 5 minutes.