ADJUSTMENTS
Each PCB assembly must be checked by check JIG set.  (Because power PCB Assembly damages to PDP Module. So be careful)
PSU(Power Supply Unit) Voltage Adjustment (Va, Vs Voltage Adjustment).
Adjust the voltages Va and Vs supplied from the PSU to the module within the specified range of each module to supply the stable power.
Adjustment (60”).  Va Voltage Adjustment
  • Connect + terminal of D.M.M to Va pin of P812 and connect –terminal to GND pin of P812.
  • Adjust VR901 voltage to match that of the label on the Top/Right of the panel. (Deviation : ±0.5V)
Vs Voltage Adjustment
  • Connect + terminal of D.M.M to Vs pin of P812 and connect –terminal to GND pin of P812.
  • Adjust VR951 voltage to match that of the label on the Top/Right of the panel. (Deviation : ±0.5V)
Connection Diagram of Power Adjustment for Measuring (Power Board): 60”
Adjustment (50”).  Va Adjustment
  • Connect + terminal of D.M.M to Va pin of P12 and connect –terminal to GND pin of P12.
  • Adjust VR951 voltage to match that of the label on the Top/Right of the panel. (Deviation : ±0.5V)
Vs Adjustment
  • Connect + terminal of D.M.M to Vs pin of P12 and connect –terminal to GND pin of P12.
  • Adjust VR901 voltage to match that of the label on the Top/Right of the panel. (Deviation : ±0.5V)
Connection Diagram of Power Adjustment for Measuring (Power Board): 50”
Adjustment(42”).   Va Voltage Adjustment
  • Connect + terminal of D.M.M to Va pin of P812 and connect –terminal to GND pin of P812.
  • Adjust VR901 voltage to match that of the label on the Top/Right of the panel. (Deviation : ±0.5V)
Vs Voltage Adjustment
  • Connect + terminal of D.M.M to Vs pin of P812 and connect –terminal to GND pin of P812.
  • Adjust VR951 voltage to match that of the label on the Top/Right of the panel. (Deviation : ±0.5V)
Connection Diagram of Power Adjustment for Measuring (Power Board): 42”(EAY32808901)