Thursday, September 12, 2013

LG 26LD330 - LCD TV - PCB Ass'y Adjustment - Software (Firmware) Update Procedure.


Mstar Main S/W Program Download
  • Connect the download jig to D-sub(RGB) jack.
  • Execute ‘ISP Tool’ program, the main window (Mstar ISP utility Vx.x.x) will be opened.
  • Click the “Connect” button and confirm “Dialog Box”
  • Click the “Config.” button and Change speed I2C Speed setting : 350 Khz ~ 400 Khz.
  • Read and write bin file.  Click “(1)Read” tab, and then load download file (XXXX.bin) by clicking “Read”.
  • Click “(2) Auto” tab and set as below.
  • Click “(3) Run”.
  • After downloading, you can see the “(4) Pass” message.
USING MEMORY STICK
  • Insert the USB memory stick to the USB port.
  • Automatically detect the SW Version. à  S/W download process is executed automatically.
  • Show the message “Copy the file from the Memory.
  • After Finished the Download, Automatically DC Off à On.
  • Check the update SW Version.