Sunday, September 23, 2012

BEKO PDPP7 SERVICE MODE - Blinking Codes.

TO ACTIVATE THE SERVICE MENU
  • When Menu is on the screen,  press [9 > 3 > 0 > 1] on the remote controller.
SERVICE MENU STRUCTURE
The display menu has three items:  Display, Caliber & Version
Display:
Display item has '7' options. 
  • Panel option gives information about the current panel resolution.  It is a Read Only.
  • Factory Mode:  Used during production, keep Off.
Scart Prescale, Nicam prescale, fm/am prescale, AGC, R|G|B Birightness Contrast are the other options.
Caliber has '9' options:  Video format, Colorspace, Test pattern, Color components, Solid field level, Initial ATS, Factory Reset, DPMS & oSD timeout.
Version:  This item gives the information about the version of the software.  
Board Layout.
TROUBLESHOOTING GUIDE
How to identify SOS Blinking signal.
  • When an abnormality has occurred in the PDP module, the protection circuit operates and reset to the stand-by mode.  At the same time, the defective PC board can be indicated  by the number of the pulse at Pin-3 [LED_R] of D8 connector on D8 board.
To check:
    Connect the V1 board to D8 connector on D board, and turn ON the power (SS34) of PDP module.
    If the power is shut down by protection circuit, the Red of LED V1 board will be shown as blinking.
LED Blinking Chart

Number of pulse
Contents & Check point

2
12V SOS [P-BOARD]
3
3.3V SOS [D-BOARD]
4
POWER SOS  [P-BOARD]
5
5V SOS [D-BOARD]
6
DRIVER SOS1 [SC BOARD]
7
DRIVER SOS2 [SU,SD,SC BOARD]
8
DRIVER SOS3 [SS BOARD]
9
FPGA CONFIG [D-BOARD]