How to enter service mode BenQ - E2400HD-LCD TV
TO ENTER FACTORY OSD MENU
  • Turn OFF the monitor.
  •  Keep pressing the "Menu" + "Enter" buttons, and turn ON the monitor.
  • Press 'Auto' button.
  • The Factory OSD will appear as below.
TO ENTER SERVICE MODE PAGE.
  • Trigger method:  Press "Menu" key & Power ON.
  • Press the "Menu" key will display the service page.
  • Press 'Menu" key will close the Service page.
  • Power OFF will quit the Service Mode.
  • At the Service Mode, the key functions are same as normal OSD define.
  • The Timer can only Reset at the Service Mode, by "Timer Reset".  Need to have a warning message to double confirm the Reset function.  The timer should record up to'99999' hours.
  • Add one select item for HDCP (DVI) port, Mode-1, Mode-2 at Service Menu;

  1. Mode-1:  To enable the hot plug pin detection. [HDMI port default]
  2. Mode-2:  To disable the hot plug pin detection [DVI port default] 
  • Add BenQ Logo On/Off item, the default is ON.
  • Add the auto power On item, the default is OFF.
  • Add the Timer Reset warning message, when select the timer reset item, then the warning message will display and need to confirm it again.  The default is 'No'.
  • Panel type define need to have the panel version.
  • F/W version need to define the dual or analog model.
Service Page illustration: