SELF CHECK
- This model has self-check functions that inform of the failure of the TV by detecting abnormality.
- Operational state is always monitored and the identified is memorized on the record.
TO ENTER SELF CHECK MODE
- Set the <SLEEP TIMER 30MIN> with [SLEEP TIMER] key.
- During the <SLEEP TIMER 30MIN> display, press [DISPLAY] key and [VIDEO STATUS] key at the same time.
- Then <TEST MODE> screen is displayed
TO EXIT FROM THE SELF-CHECK MODE
FAULT INDICATIONS & CHECK ITEMS {Click on the image to Enlarge}
- By using the remote control unit, turn the power off. At this time, the failure record is cleared.
- Take off the AC plug from the wall outlet. At this time, the failure record is not cleared.
SELF CHECK DISPLAY
EXPLANATIONS
- For X-ray protection, B1 over-current protection and low B short protection, the power of the TV is turned off if NG is detected.
- Immediately after the power is turned off, POWER LED will be turning on and off. When the power is turned off, you cannot turn the power on again until the AC plug is taken out and put in again.
- The latest failure is stored on the record at the end. The failure record for each check item is counted to the number of 9 at the maximum, When more than 9 failures are stored on the record, the counter remains stopped at 9.
- SYNC is neither counted nor stored in memory.
- Because of the timing of Vcc start-up and shut-down of the IC connecting to the I2C bus during which the power is turned on and off, the operation may be interpreted as an error. In order to avoid the misinterpretation, the self-check functions should be started at about 3 seconds after the power is turned on.
LED BLINKS INDICATIONS [WHEN THERE IS NO RASTER]
Item
|
POWER
LED ON / OFF intervals
|
X-ray
protection
|
Turning
on and off 0.1-second intervals
|
B1
over-current protection
|
Turning
on and off 1-second intervals
|
Low
B short protection
|
Turning
on and off 2-second intervals
|
MEMORY IC REPLACEMENT & SERVICE MODE
- Power off. Switch off the power and disconnect the power cord from the wall outlet.
- Replace the memory IC. Initial value must be entered into the new IC.
- Power on. Connect the power cord to the wall outlet and switch on the power.
- Press [SLEEP TIMER]key and, while the indication of SLEEP TIMER 0 MIN is being displayed, press [DISPLAY]key and [VIDEO STATUS]key on the remote control unit simultaneously.
- The SERVICE MENU screen is displayed.
- Verify what to set in the SERVICE MENU, and set whatever is necessary.
- Refer to the SERVICE ADJUSTMENT for setting.
- Press the [BACK] key twice to return normal screen.
- Receive channel setting. Refer to the OPERATING INSTRUCTIONS (USER'S GUIDE) and set the receive channels (Channels Preset) as described.
- User settings Check the user setting items according to after page. Where these do not agree, refer to the OPERATING INSTRUCTIONS (USER'S GUIDE) and set the items as described.
SERVICE ADJUSTMENT ITEMS