Wednesday, May 29, 2013

PANASONIC TH-37PX50U – TH-42PX50U – TH-50PX50U - DRIVER SETUP - QUICK ADJUSTMENTS AFTER BOARD EXCHANGE - Adjustment Volume Location - Test Points - Hotel Mode



PREPARATION 
  • Input an APL 100 % white signal.
  • Set the picture controls: -Picture mode: Normal.  White balance: Cool.  Aspect: 16:9.
ADJUSTMENTS
Adjust driver section voltages referring the panel data on the panel data label.
TH-37PX50U
TH-42PX50U
TH-50PX50U
PANEL LABEL INFORMATION
PRINTED CIRCUIT BOARD EXCHANGE
To remove P.C.B. wait 1 minute after power was off for discharge from electrolysis capacitors.
QUICK ADJUSTMENT AFTER BOARD EXCHANGE {Click on pictures to Magnify}
TH-37PX50U
TH-42PX50U
TH-50PX50U
ADJUSTMENT VOLUME LOCATION & TEST POINTS
TH-37PX50U
TEST POINTS

TH-42PX50U
TEST POINTS

TH-50PX50U
TEST POINTS

HOTEL MODE
Access command
  • Press MUTE button on remote control. Hold few seconds.
  • Press the CH ▲/▼  button and VOL ▲/▼  button to Set the data of EEPROM(ADDRESS 1584) to 01
  • Push the Power switch (button) off/on the set (the remote control) to turn the set off/on.
TO EXIT HOTEL MODE
  • First, set the data of EEPROM (ADDRESS 1584) to 00.
  • Push the Power switch (button) off/on the set (the remote control) to turn the set off/on.  Then, it is no longer hotel mode.
ACCESS COMMAND TO THE HOTEL MODE SETUP MENU
In order to display the Hotel mode setup menu, enter the following command (within 2 second).
[TV] : Vol.  + [REMOTE] : TV/VIDEO (3 times).

Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product by anyone else could result in serious injury or death. If you are not familiar with electronics, do not attempt to repair.  Whether you suffer fatal electrical shock.   Instead, contact the nearest service center.