MARANTZ - CD 6002 _ UPDATE MICROPROCESSOR SOFTWARE PROCEDURE _ 2 of 2



Contn:
                                                               2 of 2


  • Click P (Program) to start update.



  • Software is written into the microprocessor.
  • The writing of software takes about 50 seconds.
  • If the software is updated successfully, a dialog box saying "R006: Programming completed successfully." appears.
  • Click OK


  • Click the File in the menu bar and select the Exit.

  • Disconnect mains cord from the unit, and then disconnect FFC of connection JIG from the unit.
WHEN FLASH PROGRAMMER DID NOT LAUNCH
  • Open the FlashProg.ini in the Flash Programmer folder by text editor. (EX.: Notepad, etc).

  • Delete the text "OpenFile=C:\...(your PC setting)...\???. s24".

  • Save the FlashProg.ini.
  • Close the text editor.
  • Probably can launch the Flash Programmer. Go to the [A] Update Procedure step 3. [Refer previous post].