SERVICE MODE
General Remote Control
- Entry : Display èMenu èMute èPOWER KEY , Mute 1-8-2 èPower key (Press each key at intervals of within 3 seconds.)
- Exit: Turn the power off and then turn it on.
- Entry : DISPLAY KEYèFACTORY KEY(Press each key at intervals of within 3 seconds.)
- Auto Remocon KEY (Line DV) - Required to be checked.
- Exit : POWER OFF èON, FACTORY KEY
- Press the FACTORY key twice at intervals of over a second. (Pressing it once to enter into AGING mode)
- Aging mode is required when performing in Line - Required to be checked.
- MENU è Full Menu Display / Move to Parent Menu.
- Direction keys ▲/ ▼ è Item Selection by Moving the Cursor.
- Direction keys Left/Right è Data Increase/Decrease for the Selected Item.
- Source è Cycles through the active input source that are connected to the unit.
INITIAL MENU SCREEN
INITIAL DATA [FACTORY DATA]
White balance
Picture Enhancer
PW3300 [New] ==> Video Main
PW2250
LOGIC PDP DRIVER (Slave address: 0X66)
OPTION BYTE
DDC WP: PW3300 GPIO13(B6 PIN)
Sound delay PW2250 reg: 0x805h:
bit15,bit14,bit13
Aging Mode
Entry : DISPLAY key →FACTORY key (Entered into FACTORY mode)
èFACTORY key (Enter into Aging mode) or Set the Aging
mode On in the above option.
èIn the Aging mode, R, G, B, and Full White pattern
are displayed in turn at intervals of five seconds. (Implement R-G-B-F/W
pattern in Scaler.)
èMute the sound.
Exit
èLOCAL key =>
Exits the Aging mode and enters into KEY MATRIX (Panel key)
èThe Aging mode will continue even if you turn the
MASTER S/W off and turn it on, unless you complete the two above procedures.
CheckSum è The checksum of the current version is displayed when
it is launched.
Reset mode
Factory Reset
- Facory Menu => Reset
- Initialize data (User Control Data) except for the data adjusted in the Factory mode, and turn the power off (Standby mode).