Sunday, November 04, 2012

HARSPER - HL32XXB _ 32" LCD TV_FIRMWARE DOWNLOAD AND UPDATE



FIRMWARE DOWNLOAD

     First, copy the download program (.exe file) in the proper folder of your operating system to the upper folder which contains this document and firmware data. ( "/Window 98" for Windows 95, 98, Me and "/Windows 2000 xp" for Windows 2000 and xp.).


     Firmware Upgrade Before start to upgrade read whole guide carefully A. the upgrade Program needs Microsoft Windows 2000 or XP Run File name : Birch Download Win2K.exe

Setup Menu


Set up “Com Port” : Select connected Serial Port between COM1 and COM 10 (ex : COM1 or CCOM2)


Baud rate is 57600 [Default is 57600]


PORT SETUP

After setup Com Port, click port setup; choose Firmware folder and Load the file.


Select the target file, which format is only binary.


DOWNLOAD

After select Firmware file, click the “Run Download”.
Status bar is waiting for Download process like a “Ready Signal…”


If fails to download can find message “Fail to Communication”
Must close Downloader window and back to Step 1-1


After click “Run Download”, you are ready to Download. And connect AC-Power cord.
Then it starts Download.

Caution:
If AC-Power code is already connected, Pull out and re-connect 30 sec later.
Then it starts Download.


When it starts Download, existing memory in the Flash Memory will be deleted. And it will start to copy Boot Block. Herewith LED shows Amber color for 2 sec.
Have to be very careful “Power Off” and disconnection of Serial Port at this time.
LED color process: Green On(Power On) =>Amber On(Erase) =>Red Blinking (Data Copy).


Window shows the new program is being downloaded in to the flash IC.

After download, wait initialize message. {This is not applicable to Win 95/98}



     After Download, ROM will be reset. During Reset, LED shows Green and RED color alternately. It takes about 5min to Download Firmware. If it takes over 10 min, disconnect AC-Power Code for 1 min and Upgrade again.  Initialize process will be carried out after Download. During the Initialize process, The LED blinks Green and RED color alternately. If it is old version, LED shows Orange color during the Initialize Process. And after Initialize process, LED shows RED Color. DO NOT THE POWER DURING THE INITIALIZE PROCESS BUT WAIT OVER 1MIN. If LED shows Orange color, wait about 1 minute without Turning off the power.

     After Initialize the LED shows normal green color. Then you are ready to watch the TV. If you should up grade Firmware again from the beginning. Please make Sure below issues during the Download process.

     When initialize is completed "Download Complete" will be displayed.

     Be very careful when downloading.

     During erase or boot copy do not cut power and disconnect serial port.  If this happens, Main Board must be exchanged.

     When serial port is disconnected, LED will change from Red to Green for standby status.  Re-connect serial port again when LED is Red.  It starts download again.

     When Power is Off, close the window and start the download process from the beginning.




No comments: