Contn: [2]
Y-Sustain B/D
10A FUSE.
- Check FUSE [FS1(5v) ,FS2(Vs)].
- Check voltages(Vsetup,-Vy, Vscw)
- Check DIODE between GND and Y SUS output. [SUSUP(OC2) SUSDN(OC1)]. forward=0.4 ,reverse=OVERLOAD.
- Check whether output voltages agrees with voltage that represented in label.
NORMAL DIODE VALUE [FORWARD]: [0.4]
NORMAL DIODE VALUE [ REVERSE ]: [0L]
- Check whether output voltages agrees with voltage that represented in label.
- Check diode value GND between Y-SUS output.
Z-Sustain B/D
CHECK THE FUSE
CHECK INPUT VOLTAGES
- Check the FUSE.
- Check input voltages.(Va, 5V,15V)
- Check FPC out put diode value.
- Check ramp waveform.
Variable resistance of Z Ramp.
Check FPC output diode value. [Check certainly after removing FPC]
Normal diode value: [0.375 forward]
Normal diode value =Overload Reverse]
POWER PROTECTION
- It is power protection when power is off automatically within 2~3 min. from power on.
- Power protection function protect the boards when occurred short on circuits of PDP module or power problem.
- If can not impress power even after replacing PSU, find out where the short occurred.
DAEGIL PSU
ORIGIN PSU
No comments: