ADJUSTMENT PREPARATION
Connection picture of the measuring instrument [On automatic control]
- Inside pattern is used when White Balance is controlled. Connect to auto controller or push Adjustment Remote Control Power On --> Enter the Mode of White Balance, the pattern will come out.
AUTO CONTROL INTERFACE & DIRECTIONS
- Adjust in the place where the influx of light like floodlight around is blocked. Illumination is less than 10 lux.
- Adhere closely the Color Analyzer [CA210] to the module less than 10cm distance, keep it with the surface of the Module and Color Analyzers' prove vertically [80 ~ 90 Degree]
- Aging time -- After aging start, keep the power On, no suspension of power supply, and heat-run over 5 minutes.
- Using 'no-signal'or 'full white' pattern or the others check the back light on
Auto adjustment map [RS-232C]
RS-232 COMMAND
CMD ID DATA
WB 00 00 [White balance start]
Wb 00 ff [White balance end]
|
|
RS-232C Command
|
|
Min
|
|
Default
|
|
Max
|
|
Cool
|
Mid
|
Warm
|
|
Cool
|
Mid
|
Warm
|
|
R-Gain
|
jg
|
ja
|
jd
|
00
|
172
|
192
|
192
|
192
|
G Gain
|
jh
|
jb
|
je
|
00
|
172
|
192
|
192
|
192
|
B Gain
|
ji
|
jc
|
jf
|
00
|
192
|
192
|
172
|
192
|
R Cut
|
|
|
|
|
64
|
64
|
64
|
128
|
G Cut
|
|
|
|
|
64
|
64
|
64
|
128
|
B Cut
|
|
|
|
|
64
|
64
|
64
|
128
|
|
|
|
|
|
|
|
|
|
- Color temperature: Cool, Medium, Warm
- One of R gain | G gain | B gain should be kept on 0xC0, and adjust the other two lower than C0.
W/B process using adjust remote control
- After enter Service Mode by pushing the"ADJ"key.
- Enter White Balance by pushing " > " key at '6'; White Balance.
- After done all adjustments, Press "In-Start'" button and compare Tool option value with the BOM and if it is correctly the same with BOM, unplug AC cable.
- Push the "In-Stop" key after completing the function inspection. Mechanical Power Switch must be set On.
AUTO DOWNLOAD
- Push "ADJ" key to enter Service Mode.
- Enter EDID D/L Mode
- Enter 'Start' by pushing 'OK' key.
MANUAL DOWNLOAD
- Use proper signal cables for EDID Download
- Analog EDID: Pin 3 exists.
- Digital EDID: Pin 3 exists.
- Never connect HDMI and D-DSub cables at the same time.
- Use the proper cables below for EDID writing.
- Download HDMI 1, HDMI 2, separately as HDMI 1 is different to HDMI 2.
D-Sub to D-Sub Connector [For analog EDID]
For HDMI EDID: DVI-D to HDMI [or] HDMI to HDMI
Item
|
Condition
|
Data (Hex)
|
Manufacturer ID
|
GSM
|
1E6D
|
Version
|
Digital: 1
|
01
|
Revision
|
Digital: 2
|
03
|
Model name
|
HEX
|
EDID Table
|
DDC function
|
HD model
|
0000
|
00 00
|
Analog | Digital
|
Serial Number: Controlled on production line.
Month, Year: Controlled on production line.
Model Name
- Model => All
- Model Name [Hex]: 00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20
- Checksum: Changeable by total EDID data.
- Vendor Specific (HDMI)
INPUT
|
MODEL NAME [HEX]
|
HDMI 1
|
65030C001000011D
|
HDMI 2
|
65030C002000011D
|
HDMI 3
|
65030C003000011D
|
MANUAL DOWNLOAD [MODEL NAME AND SERIAL NUMBER]
- Press the "In-Start" key of ADJ remote control.
- Go to 'Menu-5' . Model number D|L' like below.
- Input Factory Model Name or serial number like photo.
- Check the model name instart menu => Factory Name displayed [ex 42LD450-ZA]
- Check Diagnostics [DTV country only] => Buyer model displayed [ex: 42LD450]
No comments: