LED LAMP BLINKING
State of lamp
|
|
|
|
|
|
Not lighted
|
Check power supply PCB
|
Check PDP Panel
|
|
Red
|
Blinks continuously
|
Power turned off immediately.
|
Check PDP panel.
|
|
Red
|
Blinks once
|
Power turned Off after 10 seconds.
|
Check-1
|
|
Red
|
Blinks twice
|
Power turned Off after 10 seconds.
|
Check – 2
|
|
Red
|
Blinks 4 times
|
Power No turned Off, LED blinks only.
|
Replace Main/Digtal PCB ass’y.
|
|
Red
|
Blinks 5 times.
|
Power not turned Off, LED blinks only.
|
Replace Video PCB Ass’y.
|
|
Green
|
Lights steadily for more than 10 seconds
|
|
|
|
|
Is on On Screen Display normal?
|
No
|
Check PDP panel.
|
|
|
|
Yes
|
|
|
|
|
All input image faulty.
|
Signal processing PCB faulty.
|
Replace Main / Digital PCB Ass’y.
|
|
|
Video input image faulty.
|
Video PCB faulty.
|
Replace Video PCB Ass’y.
|
|
|
S-Video input image faulty.
|
Video PCB faulty.
|
Replace Video PCB Ass’y.
|
|
|
Component video input image faulty.
|
Signal processing PCB faulty.
|
Replace Main / Digital PCB Ass’y.
|
|
|
RGB 1,2 input image faulty.
|
Check – 3.
|
|
TEMPERATURE
PROTECTOR OPERATED: Power Lamp Flashes intermittently Twice in Red.[for
0.5 seconds at an interval of 5 seconds]
Is ambient temperature of IC757 on Main Digital PCB less
than 60 degree C?
|
No
|
Adjust PDP unit installation so that peripheral
temperature is 40 Degree C or less.
|
|
Yes
|
|
|
|
Does unit operates normally when temperature sensor IC757
changed?
|
No
|
Microcomputer peripheral circuit faulty.
|
Replace Main/digital PCB Ass’y.
|
|
Yes
|
Temperature sensor IC757 faulty.
|
Replace temperature sensor IC757.
|
FAN PROTECTOR
OPERATED: Power Lamp Flashes once intermittently in Red [for 0.5 seconds
at an interval of 3 seconds]
Is voltage at connectors P951 3pin, P953 3pin and P954
3pin on Main/digital PCB 14V?
|
|
|
Yes
|
Fan faulty.
|
Replace the fan.
|
No
|
Microcomputer peripheral circuit faulty.
|
Replace Main/Digital PCB Ass’y.
|