SCHNEIDER TV17XL.4 TV17XL.7 TV17XL.C TV17XL.D TV17XL.E TV-17XL.F Service Mode Adjustments

Operating Voltage [+145V]
Set Contrast and Brightness to minimum.
Check point:  Cathode of [D202], against secondary ground.  Set with [R202] the measured voltage to {+145 +/- 0.5V}
AGC VOLTAGE ALIGNMENT
  • In range III [channel-8] feed in a PAL B/G test pattern without sound carrier and with an antenna input level of 65dBuV at 75 Ohms. At tuner pin-1 [AGC] and pin-3 [Gnd], connect a voltmeter and set in Service Mode following voltage:

  1. Tuner Selteka      [KS-H-132]          2.3VDC.
  2. Tuner Temic         [6002 PH5]          3.15VDC.
  3. Tuner Philips        [UV 1316-SIG-3]  2.10VDC.
TO ENTER SERVICE MODE

     Before activating Service Mode set suited test pattern.  Set medium brightness, color, contrast and sharpness, noise and picture mode. 

     A standard 4:3 test pattern is necessary for geometry adjustment.  The chassis for 16:9 requires a 4:3 test pattern covering the entire area to be set in the decoder mode, thus creating a horizontal extension [horizontal ellipses].

Go to Service Mode
  • Press the buttons [Mute => red => TV} on the remote control, one after another in sequence.
  • Use 'red' button to select menu line of digit.
  • Use 'Up' or 'Dn' button to select further parameters.
  • Press 'Vol Up or Vol Dn' buttons to change the parameters.
  • Press "OK" button to store the changes into memory.
  • Press "TV' button to EXIT service mode.
CHILD LOCK CODE GLOBAL [ON | OFF]

OFF:  During the search operation all channels are not 'prepared' for a possible activation of the child proof lock and have to be individually set.

ON:  During the search operation all channels are 'prepared' for a possible activation of the childproof lock.

CHILD LOCK CODE RESET
ON: To deactivate the childproof lock , set to 'On'.  After switching On the mains switch again, the childproof lock is switched off.

NVM addr.     0 0 0 0                     Data  0 0
  • Press the 'red' button on the remote control to select the various setting positions of the NVM address and press the volume buttons to  ( > ) | ( < ) to change them.  The complete address is a four digit figure and the corresponding data  is a two digit figure.  A chang of data from a complete address must be stored by pressing the button "OK". 