Tuesday, October 23, 2012

SAMSUNG - LN22C450E1M/LN26C450E1M/LN32C450E1M LN32C530F1M/LN37C530F1M/LN40C530F1M/ LN46C530F1M/LN52C530F1M LN32C550J1M/LN40C550J1M/LN46C550J1M _ FACTORY MODE_SERVICE MODE


TO ENTER SERVICE MODE

  • To enter service mode press the remote control keys in sequence:  If factory remote control is not available.
{Power Off => Mute => 1 => 8 => 2 => Power On}

TO ACCESS SERVICE MODE [Using customer remote control]
  • Turn the Power Off and set to standby mode.
  • Press the remote buttons {Power-Off => Mute => 1 => 8 => 2 => Power On} to turn On the set.
  • The set turns On and enters Service Mode.  This may take approximately 20 seconds.
  • Press the Power button to Exit, and store the data into memory.  If fails to enter service mode, repeat the above steps
INITIAL SERVICE MODE DISPLAY STATE
=============================================
Option
--------------------------------------------------------------------------------
ADC/WB
--------------------------------------------------------------------------------
Control
--------------------------------------------------------------------------------
Advanced: 0->0->0->0->EXIT
--------------------------------------------------------------------------------
Expert
--------------------------------------------------------------------------------
T-CRLIBRFC-xxxx(FHD), T-CRLIBRHC(HD)
T-CRLIBRS-xxxx
DTP-LP-0144-01
DTP-LP-App-0126-01
OPTION: E030 01
ADC: HDMI COMP PC AV
EDID: FAIL / SUCCESS
Build date: Month-day-year
Date of purchase
--------------------------------------------------------------------------------

HOW TO ENTER HIDDEN FACTORY MODE
  • into the factory mode
  • move the tap to Advanced
  • key input:  0 + 0 + 0 + 0
  • ** hidden menu: Advanced
BUTTONS OPERATIONS WITHIN SERVICE MODE
  1. Menu:  Full Menu Display / Move to Parent Menu.
  2. Direction keys [Up/Dn]:  Item selection by Moving the Cursor.
  3. direction keys (< / >):  Data increase or decrease for the selected item.
  4. Source:  Cycles through the active input source that are connected to the unit.




No comments: