Tuesday, March 19, 2013

SANYO PLV-Z1 - LAMP REPLACEMENT & LAMP TIME RESET - MULTIMEDIA PROJECTOR



LAMP REPLACEMENT
  • Turn off the projector and disconnect AC plug. Allow the projector to be cooled for at least 45 minutes.
  • To remove the Lamp cover, remove the screw with a screwdriver.
  • Remove 2 screws with a screwdriver and pull out the Lamp assembly by grasping the handle.
  • Replace the Lamp assembly with a new one and tighten 2 screws back into position. Make sure that the Lamp assembly is set properly. Replace the Lamp cover and tighten the screw.
  • Connect the AC Power Cord to the projector and turn on the projector
[LAMP TYPE NUMBER:  POA-LMP54]
LAMP REPLACEMENT COUNTER RESET
  1. Turn on the projector and press the MENU button. The main menu appears. Select the Setting menu with the POINT UP/DOWN button, and then press the POINT RIGHT button to enter the sub-menu.
  2. Choose the Lamp counter reset with the POINT UP/DOWN button, and then press the SELECT button.
  3. The message “Lamp replace counter reset?” is displayed.  Select "Yes" with the SELECT button, and the other confirma-tion display appears. Select "Yes" with the SELECT button to reset.
  4. The LAMP REPLACE indicator stops lighting after the Lamp Replace Counter is reset.
Do not reset the Lamp Replace Counter before the Projection lamp is replaced.