Tuesday, March 26, 2013

FUNAI - ILO - SYMPHONIC - RCA - IWT3206 - 32" ANALOG-DIGITAL COLOR TV - SD CHECK MODE - ELECTRICAL ADJUSTMENTS - INITIALIZATION - SERVICE MODE - +B VOLTAGE ADJUSTMENT - INITIAL SETTING




Use service remote control.  How to make a service remote control out of customer remote control.
  • Prepare normal remote control unit. (Part No. NE906UD)
  • Remove 3 Screws from the back lid.
  • Add J1 (Jumper Wire) to the remote control CBA.
SERVICE MODE
  • Use the service remote control unit.
  • Turn the power on. (Use main power on the TV unit.)
  • Press [SLEEP] button on the service remote control unit. Version of microcomputer will display on the CRT. (M02-0.05 N2S **)
  • Check the display on the lower left is “02” and if it is not “02” set it at “02” according to "Initial Setting".
+B VOLTAGE ADJUST
  • Purpose:  To obtain correct operation.
  • Symptom of Maladjustment:  The picture is dark and the unit does not operate correctly.
TP601, J371(GND), VR661 --- Main CBA
  1. Connect DC Volt Meter to TP601 and J371(GND).
  2. Adjust VR661 so that the voltage of TP601 becomes +132±0.5 V DC.
TO INITIALIZE
To put the program back at the factory-default, initialize the Analog/Digital Color Television as the following procedure.
  1. Use the service remote control unit.
  2. Turn the power on. (Use main power on the TV unit.)
  3. Press [SLEEP] button on the service remote control unit to enter the Service mode.
  4. Press [VOL DN] button on the service remote control unit twice, and confirm that OSD indication is “7F = FF.” If needed, set it to become “7F = FF” by pressing [CH UP | DN] buttons on the service remote control unit.
  5. Confirm that OSD indication on the four corners on TV screen changes from on and off light indication to red by pressing a [INFO] button. (It takes one or two seconds.)
  6. Turn the power off by pressing main power button on the TV unit, and unplug the AC cord from the AC outlet.
INITIAL SETTING
  • Enter the Service mode.
  • Press [VOL DN] button on the service remote control unit. Display changes “C/D”, “7F”, “VIDEO”, “AV MEMO”, “STABLE SOUND”, “300”, “YUV MEMORY”, and “NO SIG BRT” cyclically when [VOL DN] button is pressed.
  • To set the following each data value, press [CH UP | DN] buttons on the service remote control unit.
  1. 7F  à Set to “FF”.
  2. VIDEO  à Set to “V1/V2/YUV”.
  3. AV MEMO  à  Set to “OFF”.
  4. STABLE SOUND  à  Set to “OFF”.
  5. 7E DATA  à Set to “300”.
  6. YUV MEMORY  à Set to “OFF”.
  7. NO SIG BRT  à  Set to “0”.
SD CHECK MODE
  • Enter the Service mode.
  • Press [1] button on the remote control unit. The unit enters the SD-Check mode.
  • The unit starts selecting the added channel from first channel according to the memorized CH ADD/DELL data and CATV/TV data in RAM.