PROTECTIONS
The fuse is located on the ass'y-power. When either the LAMP indicator or the READY indicator is not illuminated, fuse may be opened. Check the fuse as following steps.
  • Remove the ass'y-power following to “Mechanical Disassembles”.
  • Remove the fuse from fuse holder.
  • Check the resistance of fuse by using the tester.  To install the fuse, take reversed step in the above.
OVERHEATING PROTECTION
Temperature monitor-1
When this function operates, warning-temperature-indicator flashes. And cooling fan continues operating until it becomes a normal temperature. If it continue to flush and flash does not stopped, disconnect the AC cord and investigate the cause of overheating.
Temperature monitor -2 (thermal switch SW902)