LAMP REPLACEMENT
  • When the life of Projection Lamp of this projector draws to an end, LAMP REPLACEMENT indicator lights yellow.  When a projected image becomes dark or the color of an image becomes unnatural, replacement of Projection Lamp is required.
  • For continued safety, replace with a lamp assembly of the same type.  Allow a projector to cool for at least 45 minutes before you open Lamp Cover.  The inside of a projector can become very hot.
  • Do not drop a lamp assembly or touch a glass bulb! The glass can shatter and may cause injury.
  1. Turn off the projector and disconnect AC plug. Allow the projector to cool for at least 45 minutes.
  2. Remove a screw with a screwdriver to remove Lamp Cover.
  3. Remove 2 screws with a screwdriver and pull out Lamp Assembly by grasping Handle.
  4. Replace Lamp Assembly with a new one and tighten 2 screws back. Make sure that Lamp Assembly is set properly. Replace Lamp Cover and tighten a screw.
  5. Connect AC Power Cord to the projector and turn it on.
  6. Reset Lamp Replace Counter.
Do not reset Lamp Replace Counter when Projection Lamp is not replaced.
LAMP REPLACE COUNTER
Be sure to reset Lamp Replace Counter when Lamp Assembly is replaced. When Lamp Replace Counter is reset, LAMP REPLACE Indicator stops lighting.
  1. Turn projector on, press MENU button and ON-SCREEN MENU will appear. Press POINT LEFT/RIGHT button(s) to move a red frame pointer to SETTING Menu icon.
  2. Press POINT DOWN button to move a red frame pointer to “Lamp counter reset” and then press SET button.  The message "Lamp replace counter reset?" is displayed. Move the pointer to [Yes] and then press SET button.
  3. Another confirmation dialog box appears and select [Yes] to reset Lamp Replace Counter.