[2 of 2]
POWER OFF
Symptom: No Picture (Priming doesn't flash) > Power off.
Cause | Countermeasure:
- F301 open à Exchange High Voltage Board.
- FU801 open à Exchange Digital Board.
- If short-circuited, disconnect connector between High Voltage Board and Scan Relay Board and,
- Short between NEGA-POSI on High Voltage Board à Exchange High Voltage Board.
- Short between NEGA-POSI on Scan Relay Board (U) à Exchange Scan Relay Board (U).
- Short between NEGA-POSI on Scan Relay Board (D) à Exchange Scan Relay Board (D).
- Symptom: No Picture à Power off (Priming flash).
- Cause | Countermeasure: R91 open à Exchange High Voltage Board.
Symptom: Failure in Writing à Power off.
DARK AND ROUGH PICTURE
MANY LIGHT SPOTS ON DARK PORTION