OPTICAL UNIT DISASSEMBLEY
  • Remove 3 screws (A) to remove the Polarizer Red Unit, the Polarizer Green unit and the Polarizer Blue Unit as shown.
  • Take extreme care not to damage the Polarizer Units, when servicing.
  • Make sure that no dust gets on the Polarizer Units. Clean the Polarizer Units with cleaning paper moistened with lens cleaner if necessary.
  • After replacing the Polarizer Unit, adjustment is necessary.
  • Make sure of the Mark color to distinguish the Polarizer Unit (Red, Green, Blue) as shown.
  • Remove a screw (B) as shown.  Remove the Lamp Duct.
  • Remove 2 screws (C) as shown in Fig.
  • Remove the Fuse Holder.
  • Lift the Lamp House Unit up to release 2 projections.
  • After Installing the Lamp House Unit, install the Temperature Fuse and Fuse Holder in the original position as shown in Fig.
  •  Remove 2 screws (D) as shown in Fig. 4-4-5.
  • Detach 2 tapes which is fixing the cable of the Temperature Fuse.
  • Remove the Duct Blue Unit carefully.