ELECTRONIC CONTROLLER
- Disconnect all the wiring connectors on the controller apart from the LCD/Badge plug.
- Now release the clip on the right-hand side of the controller just below the light pipes by firmly pushing it in towards the controller.
- The bottom of the controller can now be lifted out to an angle of about 45_ at which point the top of the controller will come free.
- Disconnect the LCD/Badge plug.
FILTER PLATE & ROTOR ASSEMBLY REMOVAL
- Remove the lower racks from the tub.
- Remove the drain filter assembly.
- Rotate the filter plate locknut anti-clockwise to release the filter plate from the rotor assembly.
- Lift the filter plate clear.
- Rotate the rotor locking ring anti clockwise to release it from the motor assembly and lift out.
- The rotor assembly is not serviceable.
WIRING COVER REMOVAL
- With the tub opened release the tub clips and push back the drawer rails as explained.
- Carefully release the four wiring cover clips from the front lower section of the tub taking care not to damage them.
- Release the three clips on the underside of the tub which retain the wiring cover.
- Pull the tub fully open and lift it up at the front (this makes it easier to remove the wiring cover from the rear of the tub).
- The wiring cover may now be carefully moved forward to release it from the rear of the tub.
- To reassemble first ensure that the wiring harnesses, drain hose and fill hose are clipped into their correct position.
TUB DISCONNECTION
- Disconnect the fill hose from the dispenser (water may drip).
- Disconnect the chassis harness plug from the electronic controller.
- Disconnect the element harness plug and earth wire from the element plate.
- Unclip the drain hose cuff from the motor assembly taking care not to misplace the non-return flap valve.
- Unclip the drain hose, fill hose and the wiring loom from the under side of the tub.
- Now remove the tub.
ROTOR SENSOR REMOVAL