PANASONIC - TY-TP42P10S _ TY-TP50P10S _25-POINT CALIBRATION




25 POINT ADJUSTMENTS


Prepare setting for adjusting PC
  • Create folder and copy files listed below for Excel data processing.
  • Create a folder directly onto the C Drive. C:/25PDATA
  • Copy the files and create the data folder listed below into the "25PDATA" folder.
  • 25P Adjustment Data Procssing.xls
  • Grid.exe
  • grid.ini
  • import.prm
  • data folder (C:\25DATA\data)
  • Adjustment processing result will be saved in the data folder automatically ("S/N" xls).’
Prepare setting of Excel
  • Start up the Visual Basic Editor by selecting "Tool" - "Macro" -> "Visual Basic Editor".
  • Select "Reference Setting" from "Tool".
  • Put a check mark on "SOLVER" in available references.
  • If .SOLVER.xla. doesn.t exist or does not show in references, press .reference. to select .SOLVER.xla..SOLVER.xla. should be in C\Program Files\Microsoft Office\Library\Solver.
EXPLANATION OF 25-POINT CALIBRATION

To start performing 25-point Calibration
  • Start up .LtabMon S. (Make sure the Touch Driver is not running.)
  • Press 'Sampling' Detailed sampling data box will appear.
  • Start up 'Grid.exe'
  • While touching the cross point in the top left corner with the touch pen, press .Capture (Enter Key).
  • Move to right one section and press 'Capture (Enter key)'. Repeat the same procedure to get calibration data from 5 points.
  • Move to far left corner in the second row, repeat the same procedure from left to right to get calibration data.  Collect data from all 25 points.
  • When you finish with the last point, press .Save.
  • Right-click to close 'Grid'
  • RES.dat will be saved in 25PDATA folder in C drive.
Excel data processing (Make sure the setting has been prepared before hand.)
  • Start up .25P Adjustment Data Procssing.xls. (Macro).
  • Select a number for adjusting model.
  • 1:50 inch TY-TP50P10S
  • 2:42 inch TY-TP42P10S
  • 3:58 inch TY-TP58P10S
  • 4:65 inch TY-TP65P10S
  • Process the aquired data. Press .RES - RES0.  Press .OK. According to the message dialog box.
  • Perform the data validation and defrag.  Press 'Validation & Initialization & Defrag'
  1. Press 'DATA - Export' to save result of the calibration.
  2. The data will be saved as 'importf.prm' in 25PDATA folder.
  3. Press 'Exit' to quit.
  4. Enter products serial number when asked for S/N.
  5. S/N.xls. will be saved in 25PDATA folder.
  6. Import the aquired data.
  7. Press 'Parameter' in LTabMonS.

  • Press 'Load File' to open 'importf.prm' file saved in 25PDATA folder.
  • The result will be imported and reflect to each parameter.
  • Press 'Write to ROM' to write.
  • Exit 'LtabMon' to finish.
PRECISE CALIBRATION
  • Make sure the LtabMonS is not running. Start up the 'Touch Driver'
  • Press 'precise calibration' from the driver.s setup panel.
  • “precise calibration” dialog box will appear.
  • Press”OK”.
  • Touch the “X” marker in the top right corner (shown in yellow) with the touch pen to stop.
  • When the driver capture XY coordinates, the yellow “X” marker moves one to right.
  • Capture XY coordinate for each "X" marker shown in yellow.
  • Get data from all 25 points.
  • When you finish collecting data from all points, the calibration result will be asked.
  • Then press ‘OK’ to exit.
CHECK FOR CALIBRATING RESULT [TEST]
  • Exit the driver.s setup panel, and touch any marker to test.
  • Point positions should not be too far off. It should be whithin 5 mm.
  • In order to test, set the setting to 0 (zero) in the “Allowance for point position differences” in the setup panel of Touch Driver.