TO ENTER SERVICE MODE
- While pressing [VOLUME ( - )] button of the main unit, press [INFO] button of the remote control three times within 2 seconds.
KEY COMMANDS
- 1. button...Main items Selection in forward direction
- 2. button...Main items Selection in reverse direction
- 3. button...Sub items Selection in forward direction
- 4. button...Sub items Selection in reverse direction
- Value is shown as a hexadecimal number.
- Preset value differs depending on models.
- After entering the adjustment mode, take note of the value in each item before starting adjustment.
TO EXIT SERVICE MODE
- Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
SERVICE TOOL MODE
- Select “SRV-TOOL” in Service Mode.
- Press [OK] button on the remote control.
DISPLAY OF SOS HISTORY
Note : To display TIME/COUNT
menu, highlight position, then press MUTE for (3sec).
Time : Cumulative power on
time, indicated hour : minute by decimal
Count : Number of ON times by
decimal
Note
: This indication will not be cleared by either of the self-check or any other
command.
TO EXIT: Disconnect
the AC cord from wall outlet.
HOTEL MODE
- In order to display the Hotel mode setup menu, enter the following command (within 2 second).
- [TV] : Vol. “Down” + [REMOTE] : TV/VIDEO (3 times)
- Then, the Hotel mode setup menu is displayed.
- To exit the Hotel mode setup menu Disconnect AC power cord from wall outlet.
TROUBLESHOOTING
Use the self-check function
to test the unit.
Checking the IIC bus lines
Power LED Blinking timing
CHECK OF IIC BUS LINE
- Self-check indication only:
Produce TV reception screen,
and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on
the remote control for more than 3 seconds.
- Self-check indication and forced to factory shipment setting:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote control for more than 3 seconds.
- TO EXIT: Disconnect the AC cord from wall outlet.
POWER LED BLINKING TIMING CHART
- When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
BLINKING TIMES
|
CONTENTS
|
CHECK POINT
|
1
|
No particular check point
Panel status.
STB 5V Sense Time Out
|
A-Board
|
2
|
15V SOS
|
A-Board
|
3
|
3.3V SOS
|
A-Board
|
4
|
Power SOS
|
P-Board
|
5
|
5V SOS
|
A_Board
|
6
|
Driver SOS-1 [SC energy
recovery unit]
|
SU-Board
SD-Board
SC-Board
|
7
|
Driver SOS-2 [SC floating
voltage area]
|
SU-Board
SD-Board
SC-Board
|
8
|
Driver SOS-3 [SS energy
recovery unit]
|
SS-Board
SS2-Board
SS-3 Board
|
9
|
Panel Config SOS
|
=====
|
10 |
Sub 5V SOS
Main 3.3V SOS
DTV 9V SOS
Tuner Power SOS
|
A-Board
|
11
|
Won’t occur
|
|
12
|
Sound SOS
|
A-Board
|
13
|
Communication error with IC8001
[Pesks Lite 2]
|
A-Board
|