Saturday, January 26, 2013

SAMSUNG SYNCMASTER 740NW _ 940NW _DISASSEMBLE PROCEDURE _ LCD MONITOR





DISASSEMBLE PROCEDURE

  • Place the monitor on a table so that its back is towards you, as shown in the left figure.  Remove the three (3) screws at the bottom of the back cover that hold it in place.
  • Turn the monitor so that its front part is towards you. Pry the front and back covers apart using your fingers.

  • Remove the front cover.
  • Turn the monitor so that its front part is looking downwards. Then remove the back cover.
  • Remove the lamp protection shield on the left of the shield (back cover). Then remove the two (2) lamp wires and the function connector.  (Be careful Shield.)

  • Lift up the shield. Check and remove the connections between the FFC cable and the panel. Then remove the shield from the panel.
  • Remove 2 screws.
  • Turn the shield so that its inside looks upwards.  Remove all the screws on the main board and the IP board (total 4 screws). Then remove the protection shield at the bottom of the IP board.

  • Main board & IP board.
  • Reassembly procedure are in the reverse order.