TO ENTER ADJUSTMENT MODE
- Using the R-side control buttons with the set turned off (standby) can activate it.
- Press the [SUB-POWER] button, [INPUT SELECT] button and [DOWN] button at the same time and hold for more than 5 seconds.
- The set turns on in adjustment mode with OSD.
TO SELECT ITEMS & DATA VALUES.
- When the set is in adjustment mode, the cursor [LEFT | RIGHT | UP | DN] and OK buttons of the remote control or R-side control buttons may be used as the adjustment keys.
- [UP | DN] buttons are used for selecting adjustment code.
- [LEFT | RIGHT] buttons are used for changing data values.
- [OK] button is used for confirming the data.
- After finishing the necessary adjustment press [MENU] button. Adjustment mode is released and the set returns to normal condition.
MEMORY INITIALIZATION
NOTE: The execution of this function returns the adjustment codes
to the preset values, therefore, adjustment
data will be lost.
- Enter Adjustment Mode.
- Select MEMORY INIT adjustment code (No.898) and change the data value from 0 to 1.
- Activate MEMORY INIT by pressing OK button.
- Select [No.712] and change data value from 1 to 0.
- Check that the receiving channel goes to P1. Unit is set to preset values.
- Select [No. 894] of Service Adjustment Menu.
- ( When No.894 is displayed as “65535” select [No.893] and change data value from 0 to 1.
- Check No.894 is displayed as “0”.)