TO ENTER ADJUSTMENT MODE
  • Using the R-side control buttons with the set turned off (standby) can activate it.
  • Press the [SUB-POWER] button, [INPUT SELECT] button and [DOWN] button at the same time and hold for more than 5 seconds.
  • The set turns on in adjustment mode with OSD.
TO SELECT ITEMS & DATA VALUES.
  • When the set is in adjustment mode, the cursor [LEFT | RIGHT | UP | DN] and OK buttons of the remote control or R-side control buttons may be used as the adjustment keys.
  •  [UP | DN] buttons are used for selecting adjustment code.
  • [LEFT | RIGHT] buttons are used for changing data values.
  • [OK] button is used for confirming the data.
  • After finishing the necessary adjustment press [MENU] button. Adjustment mode is released and the set returns to normal condition.
MEMORY INITIALIZATION
NOTE: The execution of this function returns the adjustment codes to the preset values, therefore, adjustment data will be lost.
  • Enter Adjustment Mode.
  • Select MEMORY INIT adjustment code (No.898) and change the data value from 0 to 1.
  • Activate MEMORY INIT by pressing OK button.
  • Select [No.712] and change data value from 1 to 0.
  • Check that the receiving channel goes to P1. Unit is set to preset values.
TO CHECK THE USE ACCUMULATION TIME FOR PANEL
  •  Select [No. 894] of Service Adjustment Menu.
  • ( When No.894 is displayed as “65535” select [No.893] and change data value from 0 to 1. 
  • Check No.894 is displayed as “0”.)