The identification of errors within the WAX chassis is
triggered in one of two ways :-
1: Busy or 2: Device failure to respond to IIC.
In the event of one of these situations arising the software will first try to
release the bus if busy (Failure to do so will report with a continuous flashing
LED) and then communicate with each device in turn to establish if a device is
faulty.
If a device is found to be faulty the relevant device number will be
displayed through the LED (Series of flashes which must be counted).
LED BLINKING CODES
LED BLINKS
|
DETAILS
|
02
|
Power Supply (PA) Protection Error
|
03
|
Power Supply (PB) Protection Error
|
04
|
Panel Error
|
05
|
DC Alert Protection Error
|
06
|
Speaker Protection Error
|
07
|
AC Det / OVP
|
08
|
Digital Error
|
09
|
Tuner Error
|
10
|
Sound Processor Error
|
11
|
Video Processor (SVP-EX) Error
|
12
|
Chroma Decoder (CXA2163) Error
|
13
|
AV Switch (CXA2069) Error
|
14
|
RTC IC Error
|
15
|
Temperature Sensor (LM75) Error
|
16
|
Port Expander 1 Error
|
17
|
Port Expander 2 Error
|
18
|
Port Expander 3 Error
|
19
|
NVM Error
|
20
|
IIC Bus Error
|
KLV-32SA10 _ MAIN BOARD
KLV 32SA10 _ LCD CONTROL [T'CON] BOARD
KLV 32SA10 _ G2 - POWER BOARD