Sunday, January 13, 2013

SHARP LC-32AD5SE405 _ VCTP SOFTWARE UPDATE PROCESS




VCTP SOFTWARE UPDATE

Before Update the VCTP Software, it is necessary to install the WRITING TOOLS into the PC

  • Unplug the AC cord, and remove the back cabinet.
  • Short circuit the 1 pin and 2 pin of CP802 on the Main PCB.
  • Insert the AC cord.
  • Remove the short circuit 1 pin and 2 pin of CP802 on the Main PCB.
  • Set the EU LCD MICON VER UP ROM DISC (JG176) to PC.
  • Start the "VCTP" (Writing Tools).
  • Select the "LPT Preferences" from File/Preferences menu, then input "5" to the value of "Delay", and press "OK".  NOTE: This step is not necessary from next time.
  • Using the MICON PROGRAM JIG KIT 25-4 (JG203), connect the PC Terminal and 1~4 pin of CP802 on the Main PCB (JG203(Red line) =1 pin of CP802).
  • Press the “TVT”.
  • Remove the check of “Bootloader Version”, and check it again.
  • When the number of the side of the check box becomes 40, you can proceed to next step.
  • If the number doesn’t become 40, check the connection and try again from step 1.
  • Press the “Erase Flash”.  Then, press the “Load Bin -> Flash” twice.
  • Press the [ ---- ] and select the writing Firmware.
  • Select the “Address", then input the ”0x7ffff", and press the “OK
  • Press the “Load Bin -> Flash”.
  • The following window will appear, then writing will start. After the finishing of the writing, window will close.
  • Finish the writing, unplug the AC cord, and remove the MICON PROGRAM JIG KIT 25-4 (JG203).
  • Insert the AC cord again, turn on the power.
  • Press both VOL. DOWN button on the set and Channel button (2) on the remote control for 2 seconds.
  • Confirm that displayed version agreement with writing.