REQUIRED EQUIPMENT
- Computer with Windows 95, Windows 98, or Windows NT.
- MTI-2031 DDC MANAGER JIG
AUTOMATIC COLOR ADJUSTMENT
- To input video, use 16 gray or any pattern using black and white.
- Select english for OSD language.
- Press the " (Enter/Source)" key for 5 seconds.
DDC - EDID DATA INPUT
- Input DDC EDID data when replacing AD PCB.
- Receive/Download the proper DDC file for the model from HQ quality control department.
OSD ADJUSTMENT WHEN REPLACING PANEL
- Adjust brightness and contrast to 0.
- Then, press the (Enter/Source) key for 5 seconds.
- Service function OSD will appear on screen.
- Press the + key to place the cursor on the panel. Press the menu key for 5 seconds.
OSD ADJUSTMENT WHEN REPLACING LAMP ONLY
- Adjust brightness and contrast to 0. Then, press the exit key for 5 seconds.
- Service function OSD will appear on the screen.
- Press the + key. Select upper lamp and press the menu key for 5 seconds.
- Then, select lower lamp and press the menu key for 5 seconds.
SERVICE FUNCTION: TO DISPLAY SERVICE FUCNTION
- The value for brightness and contrast should be changed to zero.
- Within 5 seconds, press the (Enter/Source) key.
- Service function OSD will be displayed.
- To disable the service function OSD, you will have to power off.
The
service function OSD is based on a grid of 29 columns x 12 rows.
The service function OSD consists of panel information,
software version and MICOM checksum.
TO CONTROL SERVICE FUNCTION OSD
- With the panel selected on OSD, whenever you press the right key, the base color will change to blue from "Panel" to "Upper Lamp", "Lower Lamp".
- After changing the panel or lamp, must reset service function OSD.
The case of panel change:
- After changing the panel, press the menu key within 5 seconds.
- Then, panel Ch. No increases one step and the panel time information is reset to zero.
- Simultaneously, other information is reset to zero (Upper/Lower lamp, Panel cycle).