REPLACING MEMORY IC
- Initial total of MEMORY IC, MICON VERSION, Digital TV MICON Firmware and POWER ON TOTAL HOURS can be checked on the screen. Total hours are displayed in 16 system of notation.
- If you set a factory initialization, the total hours is reset to "0", refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding.
- Turn on the POWER, and set to the TV mode.
- Set the VOLUME to minimum.
- Press both VOL. DOWN button on the set and Channel button (2) on the remote control for more than 2 seconds.
- After the confirmation of MICON VERSION and Digital TV MICON Firmware, turn off the power.
CONFIRMATION OF INITIAL DATA
If a service repair is
undertaken where it has been required to change the MEMORY IC, the following
steps should be taken to ensure correct data settings.
- Turn on the POWER, and set to the TV mode.
- Set the VOLUME to minimum.
- Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
- ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the ADDRESS until required ADDRESS to be changed is reached.
- Press LEFT/RIGHT button to select DATA. When DATA is selected, it will "blink".
- Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
- Pressing LEFT/RIGHT button will take you back to ADDRESS for further selection if necessary.
- Repeat steps 4 to 6 until all data has been checked.
- When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
AFTER THE DATA INPUT, SET TO THE INITIALIZATION OF SHIPPING
- Turn on the Power.
- Set the VOLUME to minimum.
- Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
- After the finishing of the initializing of shipping, the unit will turn off automatically.
- The unit will now have the correct DATA for the new MEMORY IC.