SERVICE MODE & ADJUSTMENT PROCEDURE
- This set has a service mode function that looks like this:
- As you can easily repair, reviewed and adjusted.
- Service mode function does not work when the clock is set.
- If the clock is set to the state should not set the clock to unplug the AC cord once.
- Down volume à 1 à Initialization for shipping. Caution: Do not use in normal service
- Down volume à 6 à Verifying the initial configuration of the memory IC.
- Down volume à 8 à Initialization of EEPROM. Caution.: Do not use in normal service
- Down volume à 9 à Adjustment holds the screen.
- Note: To set the clock to unplug the AC cord.
- Set the volume to the minimum.
- Press the key for more than 2 seconds of remote control transmitter at the same time of the channel (6) and the Volume Down key on the main body of the set.
- To match the address in the up / down volume keys of the remote control transmitter.
- When you press the key decision of remote control transmitter, the data flash is selected.
- In the up / down volume key remote control transmitter, decide to fit the data and press the key.
- Verify that the unit of the data repeat the above
- Finish checking data after checking the data Power OFF the set.
- Switch it back ON again.