CHECKS {2 of 2}
[HCD-S500/S800 are the amplifier, DVD/CD and tuner section in DAV-S500/S800.]
- Peripheral
Data write à read, and accord check
Error 03: EEPROM write/read
discord
Data 0x9249, 0x2942, 0x4294
are written to addresses 0x00~0xFF of EEPROM (IC101), then read and checked.
Before writing, the data are saved, then after
checking, they are written to restore the contents of EEPROM- Servo
Data write à read, and accord check
Error 12: Read data discord
Data 0x9249, 0x2942, 0x4294
are written to the address 0x602 of RAM in the Servo DSP (IC302), then read and
checked.
- DSP Driver Test
Error: Not detected.
Caution: Do not conduct this
test with a mechanical deck connected.
The maximum voltage is
applied to the Servo Driver IC (IC401, IC802). If mechanical deck is connected,
the motor and optics could be damaged.
Disconnect mechanical deck
following the output message, then enter specified 4- or 5-digit number from
the remote commander, and press the [ENTER].
The test is conducted only
when the input data accord. Check the output level, then press the [NEXT]
to finish the
test.
This test is skipped if “All”
is selected.
[Disconnect flat cables
connected to the CN009 and CN010 of MB-82/85 board. Also, disconnect harness
from the CN402.]
- Supply
An access is made to the
stream supply and servo control IC (IC302) and external RAM (IC303) using check
data.
If mechanical deck is
connected, the motor and optics could be damaged. This check is also executed
by the “All” menu item.
[Disconnect flat cables
connected to the CN009 and
CN010 of DVD board. Also,
disconnect harness from the CN402.]
- ARP Register Check
Error 08: ARP register write,
and read data discord
Data 0x00 to 0xFF are written to the TMAX
register (address 0xC6) in ARP (IC302), then they are read and checked.- ARP to RAM Data Bus
Error 09: ARP ß-> RAM
data bus error
Data 0x0001 to 0x8000 where
one bit each is set to 1 are written to the address 0 of RAM (IC303) connected
to the ARP (IC302) through the bus, then they are read and checked. In case of
discord, written bit pattern and read data are displayed. If data where
multiple bits are 1 are read, the bits concerned may touch each other.
Further, if data where
certain bit is always 1 or 0 regardless of written data, the line could be
disconnected or shorted.
- ARP to RAM Address Bus
Error 10: ARP à RAM address bus error
Caution: Address and data
display in case of an error is different from the display of other diagnosis
(described later).
Before starting the test, all
addresses of RAM (IC303) are cleared to 0x0000.
First, 0xA55A is written to
the address 0x00000, and the address data are read and checked from addresses
0x00001 to 0x80000 while shifting 1 bit each.
Next, the data at that
address is cleared, and it is written to the address 0x00001, and read and
checked in the same manner.
This check is repeated up to
the address 0x80000 while shifting the address data by 1 bit each.
If data other than 0 is read
at the addresses except written address, an error is given because all
addresses were already cleared to 0.
In this check, the error
display pattern is different from that of other diagnosis; read data, written
address, and read address are displayed in this order. However, the message
uses same template, and accordingly exchange Address and Data when reading.
The following display, for example:
===============================
###
Syscon Diagnosis ###
5-4. ARP
to RAM Address Bus
Error 10:
ARP - RAM Address B
Address :
0000A55A
Write
Data : 00000000
Read Data
: 00080000
Press
NEXT Key to Continue
Press
PREV Key to Repeat
===========================
shows the data 0xA55A was
read from address 0x00080000 though it was written to the address 0x00000000.
This implies that these
addresses are in the form of shadow. Also, if the read data is not 0xA55A,
another error will be present.
- ARP RAM Check
Error 11: ARP RAM read data
discord
The program code data stored
in ROM are copied to all areas of RAM (IC303) connected to the ARP (IC302)
through the bus, then they are read and checked if they accord.
If the detail check was selected
initially, the data are written to all areas and read, then the same test is
conducted once again with the data where all bits are inverted between 1 and 0.
If discord is detected,
faulty address, written data, and read data are displayed following the error
code 11, and the test is suspended.
- AV Decoder
Data write à read, and accord check
Error 13: AVD RAM read data
discord
The program code data stored
in ROM (IC107 or IC108) are copied to all areas oo»RAM (IC504, IC505) connected
to the AVD (IC503) through the bus, then they are read and checked if they
accord. Further, the same test is conducted once again with the data where all
bits are inverted between 1 and 0. If discord is detected, faulty address,
written data, and read data are displayed following the error code 13, and the
test is suspended.
- 1930 SP
Error: Not detected.
The data including sub
picture streams in ROM (IC107 or IC108) are transferred to the RAM (IC504,
IC505) in AVD (IC503), and output as video signals from the AVD (IC503).
They are output from all
video terminals (Composite, Y/C).
Video
Color Bar
AVD color bar command write à Video OUT
Error: Not detected.
The command is transferred to
the AVD, and the color bar signals are output from video terminals.
They are output from all
video terminals (Composite, Y/C).
Composit Out
Y/C Out
Component Out
- Audio
Error 14 : ARP à 1930 video NG
Error 15 : ARP à 1930 audio NG
Test Tone
All channels
2ch Left
2ch Right
Front Left
Front Right
Rear Left
Rear Right
Center
Sub Woofer- DSD Decoder
2752 RAM Check
- Error Codes List
01: RAM write/read data
discord
02: Gate array NG
03: EEPROM NG
08: ARP register read data
discord
09: ARP <--> RAM
data bus error
10: ARP ß> RAM address bus error
11: ARP RAM read data discord
12: Servo DSP NG
13: 1930 SDRAM NG
14: ARP → 1930
video NG
15: ARP → 1930
audio NG
16: 1910 UCODE download NG
17: System call error
(function not supported)
18: System call error
(parameter error)
19: System call error
(illegal ID number)
20: System call error (time
out)
90: Error occurred
91: User verification NG
92: Diagnosis cancelled
- DRIVE AUTO ADJUSTMENT
==============================
## Drive
Auto Adjustment ##
Adjustment
Menu
0. ALL
1. DVD-SL
2. CD
3. DVD-DL
4. LCD
Exit:
RETURN
===========================
Normally, [0]
is selected to
adjust DVD (single layer), CD, DVD (dual layer), and SACD in this order. But,
individual items can be adjusted for the case where adjustment is suspended due
to an error.
In this mode, the adjustment
can be made easily through the operation following the message displayed on the
screen. The disc used for adjustment
must be the one specified for adjustment. However, for SACD disc, use the
player with initial data if the disc is not available.
- ALL
Then, 1. DVD-SL disc, 2. CD
disc, 3. DVD-DL disc, and 4. SACD disc
are adjusted in this order. Each time one disc was adjusted, it is ejected. Replace
it with the specified disc following the message. Though the message to confirm
whether discs other than SACD disc are adjusted is not displayed, you can
finish the adjustment if pressing the x button. During adjustment of
each disc, the measurement for disc type judgment is made. As automatic
adjustment does not judge the disc type unlike conventional models, take care
not to insert wrong type discs. Also, do not give a shock during adjustment.
DVD-SL (single layer)
Select [1], insert DVD single layer
disc, and press [ENTER] key, and the adjustment will be made through the
following steps, then adjusted values will be written to the EEPROM.
- DVD Single Layer Disc Adjustment Steps
2. Disc Check Memory SL
3. Wait 300 msec
4. Set Disc Type SL
5. LD ON
6. Spdl Start
7. Wait 1 sec
8. Focus Servo ON 0
9. Auto Track Offset Adjust
10. CLVA ON
11. Wait 500 msec
12. Tracking ON
13. Wait 1 sec
14. Sled ON
15. Check CLV Lock
16. Auto LFO Adjust
17. Auto Focus Offset Adjust
18. Auto Tilt Position Adjust
19. Auto Focus Gain Adjust
20. Auto Focus Offset Adjust
21. EQ Boost Adjust
22. Auto LFO Adjust
23. Auto Track Gain Adjust,
Search Check
24. 32Tj Fwd
25. 32Tj Rev
26. 500Tj Fwd
27. 500Tj Rev
28. All Servo Stop
29. Eep Copy Loop Filter
Offset
- Select [2], insert CD disc, and press [ENTER] key, and the adjustment will be made through the following steps, then adjusted values will be written to the EEPROM.
1. Sled Tilt Rest
2. Disc Check Memory CD
3. Wait 500 msec
4. Set Disc Type CD
5. LD ON
6. Spdl Start
7. Wait 500 msec
8. Focus Servo ON 0
9. Auto Track Offset Adjust
10. CLVA ON
11. Wait 500 msec
12. Tracking ON
13. (TC Display Start)
14. Wait 1 sec
15. Jitter Display Start
16. Sled ON
17. Check CLV ON
18. Auto LFO Adjust
19. Auto Focus Offset Adjust
21. Auto Focus Gain Adjust
22. Auto Focus Offset Adjust
23. Eq Boost Adjust
24. Auto LFO Adjust
25. Auto Track Gain Adjust,
Search Check
26. 32Tj Fwd
27. 32Tj Rev
28. 500Tj Fwd
29. 500Tj Rev
30. All Servo Stop.
- DVD-DL (dual layer)
DVD Dual Layer Disc
Adjustment Steps
1. Sled Tilt Reset
2. Disc Check Memory DL
3. Wait 500 msec
4. Set Disc Type DL
5. LD ON
6. Spdl Start
7. Wait 1 sec, Layer 1 Adjust
8. Focus Servo ON 0
9. Auto Track Offset Adjust
10. Clva ON
11. Wait 500 msec
12. Tracking ON
13. Wait 500 msec
14. Sled ON
15. Check CLV Lock
16. Auto Loop Filter Offset
Auto Focus Adjust
17.
18. Auto Focus Gain Adjust
19. Auto Focus Offset Adjust
20. Eq Boost Adjust
21. Auto Loop Filter Offset
22. Auto Track Gain Adjust,
Search Check
23. 32Tj Fwd
24. 32Tj Rev
25. 500Tj Fwd
26. 500Tj Rev, Layer 0 Adjust
27. Fj (L1 à L0)
28. Auto Track Offset Adjust
L0
29. Clva ON
30. Wait 500 msec
31. Tracking ON
32. Wait 500 msec
33. Sled ON
34. Check CLV Lock
35. Auto Focus Filter Offset
36. Auto Focus Adjust
37.
38. Auto Focus Gain Adjust
39. Auto Focus Offset Adjust
40. Eq Boost Adjust
41. Auto Loop Filter Offset
42. Auto Track Gain Adjust,
Search Check
43. 32Tj Fwd
44. 32Tj Rev
45. 500Tj fwd
46. 500Tj Rev, Layer Jump
Check
47. Lj (L0 à L1)
48. Lj (L1 à L0)
49. All servo stop */
- LCD
However, if SACD disc is not available, use the player with initial data, skipping the SACD adjustment. In this case, you can finish the adjustment if pressing the [Stop] button.
SACD Adjustment Steps
1. Sled Tilt Reset
2. Set Disc Type CD
3. LD ON
4. Spdl Start
5. Wait 500 msec
6. Focus Servo ON 0
7. Auto track Offset Adjust
8.
9. CLVA ON
10. Wait 500 msec
11. Tracking ON
12. Wait 1 sec
13. Sled ON
14. Check CLV ON
15. Auto Focus Offset Adjust
17.
18. Auto Focus Gain Adjust
19. Auto Focus Offset Adjust
20. Eq Boost Adjust
21. Auto LFO Adjust
22. Auto Track Gain Adjust
23. 32Tj Fwd
24. 32Tj Rev
25. 500Tj Fwd
26. 500Tj Rev
27. All Servo Stop */
- DRIVE MANUAL OPERATION
==================================
## Drive
Manual Operation ##
Operation
Menu
1. Disc
type
2. Servo
Control
3.
Track/Layer Jump
4. Manual
Adjustment
5. Auto
Adjustment
6. Memory
Check
7. Sacd
Water Mark
0. Disc
Check Memory
_
Exit:
Return
==============================
In using the manual operation
menu, take care of the following points. These commands do not provide
protection, thus requiring correct operation. The sector address or time code
field is displayed
when a disc is loaded.
1. Set correctly the disc
type to be used on the Disc Type screen.
The disc type must be set after a disc was loaded. The set disc type is cleared when the tray
is opened.
2. After power ON, if the
Drive Manual Operation was selected, first perform “Reset SLED TILT” by opening
1. Disc Type screen.
3. In case of an alarm,
immediately press the [Stop] button to stop the servo operation, and turn the
power OFF.