SERVICE MODE [FACTORY MODE]
  • To enter “Service Mode” Press the remote -control keys in this sequence : If you do not have Factory remote – control.
[POWER OFF à MUTE à 1 à 8 à 2 à POWER ON]
  • If you have a factory remote control.
[POWER ON à INFO à FACTORY]

EDID INPUT METHOD
  • SAMSUNG LCD TV support the DDC control JIG.  You can see the connection between PC and LCD TV.                 execute "WinDDC.EXE"
  • Click "Open[F5]"
  • Select Connected Port#1 and Click Next OK
Find file name :
15 inch : VE15
17 inch : VC17
20 inch : VC20
  • Click Next (OK) button.
  • Select enter button (on Key-Board) After Monitor S/N input.
  • Check "DDC OK".


MICOM TDA15001H [PROGRAM UPGRADE]
PROGRAM UPGRADE JIG

                                                   Connect the parallel Port
Connect Jig to CN905 on PCB Ass'y

Click " WISP " Icon on Computer.
Check "Automatic mode on".

Click "Browser" button : Select the Code , Click "Auto Execute" button Check Erase and Write OK In "General" window and check Verify OK in "ISP status" window.