DRIVING COMPARTMENT TEST MODE
- Hold
down “1” and “2” keys simultaneously and then press POWER S/W “4” on. (Whole lamps turn on and display show “t1”
after 2 Seconds.)
- The
driving compartment can be tested when you press “3” key right after entering into
the initial stage of the TEST MODE.
DRIVING COMPARTMENT TEST
Pre-wash
VALVE ON(0.3sec) → OFF(0.3sec) → COLD VALVE ON(0.3sec) → [OFF(0.3sec) → HOT
VALVE ON (0.3sec):OPTION ] → OFF(0.3sec) → Pump MOT OR
ON(0.3sec) → OFF(0.3sec) → MOTOR Left (1.0sec) → OFF(0.5 sec) → MOTOR Right
(0.5sec) → OFF(0.3sec) → HEATER RELAY ON(0.3sec)→ OFF(0.3sec) → DOOR OPEN (Function
continues when door is closed).
THERMISTOR TEST MODE
- Hold
down “1” and “2” keys simultaneously and then press POWER S/W “4” on. (Whole
lamps turn on and display show “t1” after 2 Seconds.)
- Press
the “Delay start” key and display shows “t2”.
- Press
the “Start/Pause” key and display shows the inside temperature of tub.
An
occurrence of an Error will make a sound of error melody for 5sec and
continuously show one of the Error Displays from the following errors. (But,
Fault Check Led will flash for 0.5sec.)
All of the steering parts will be off at that
time until that error was released.
If there
is no higher change in water frequency than 100Hz for 2 minutes during the
initial time of water supply and if water level doesn’t reach the preset level
in 10 minutes, this error will occur. This
error will be released using Start/Pause button, which performs the initial
condition of operation. [ Display : “4E”]
If water
level frequency is still lower than the reset level frequency (25.20kHz) in 10
minutes after starting of water drain, this error will occur. This error will be released using
Start/Pause button, which performs the initial condition of operation. [
Display : “5E”]
If an
abnormal water level frequency is sensed (for occurrence of Over Flow
:21.00kHz), Auto Power Off may release this error and continuously progress
water drain until the frequency reached 25.00kHz. If Over Flow is also
sensed even after the following check of water level frequency indicating that
error, it functions to progress water drain. [ Display : “OE”]
This
error will be released by closing Door. [ Display : “door”]
This
error will be released by pressing start/pause S/W. [ DISPLAY : “ UE”]
This
error will be released by turning off Power S/W. [ Display : “HE1”(Over Heat),]
[ Display : “HE2”, indicating no operation of HE.]
- Pressure
S/W (Single Part Trouble) Error.
Frequency
signals(kHz) generated by water level S/W.
Water
Level
|
Low
|
High
|
Abnormal
Frequency
|
30.00
KHz
|
15.00
KHz
|
If the
above frequency signals are displayed longer than 5sec, it indicates Pressure
S/W Error. Drain water for 3 minutes for that Error, and turn OFF water drain
pump. Pressure S/W Error display “ IE” will be shown.
- Abnormal
Water Temperature ERROR
Water
drain begins if abnormal water temperature is sensed at the initial time of
water supply. If the frequency higher than 25.20KHz is sensed, water will be
drained by force. [ Display : “CE”] This error will be released by turning off
Power S/W.
- Natural
Drain/Water Leak Error
If more
than 4 times of water supply and safe water level of Heater are sensed for each
course, this error will occur. [ Display : “LE]. This error will be
released by turning off Power S/W.
If Motor
Tacho is abnormal, this error will occur.
If Tacho signals are inputted
less than 2 for 2sec after Motor started, this error will occur. [ Display : “3E”]. This
error will be released by turning off Power S/W.
If Tacho
signals are inputted more than 300 every 1sec in the operational interval less
than 90RPM, this error will occur. Turn
off Power S/W at that time. [ Display : “bE”].
This error will be released by
turning off Power S/W.
- Thermistor
Abnormal Error
If
Thermistor circuit is abnormal, this error will occur. If Thermistor is lower than 0.2V or higher
than 4.5V, this error will occur. [ Display :”tE”]. This error will be
released by turning off Power S/W.