W/B & LUMINANCE
Approximately 30 minutes should be allowed for warm up before proceeding white balance adjustment.
- YPbPr Mode display adjustment
- White balance adjustment (B)
Equipment
Requirements:
- Minolta CA-110 or Equivalent Color analyzer Quantum Data Pattern Generator 802G , 802BT or equivalent instrument Input requirements:
- Input Signal Type: YPbPr signal
- 720P mode, TVBar100 pattern by 802G or 802BT.
- Select Smart picture to User mode and check the x, y data.
- Input Signal Strength: 1 Vpp for Y signal; 700 mVpp for Pb & Pr signal
- Input Injection Point: YPbPr (RAC jack)
- Select source as “Component”.
- Set Smart picture as “User” and to be Contrast =50(TBD) (CMO), Brightness=50(TBD) (CMO), at normal menu mode.
- Apply “TVBar100” pattern with color bar pattern by signal generator.
- Enter factory mode menu: press “MENU+ “234” then enter FAC mode.
- At FAC mode menu, select FACTORY->Picture ->ADC -> Auto Colour item. Then press “>” key to adjust ADC_GAIN_R, ADC_GAIN_G, ADC_GAIN_B and DC_OFFSET_R, ADC_OFFSET_G, ADC_OFFSET_B. Then store those values to NVM.
- Select source as “HDMI1”
- Apply Flat pattern (100% white pattern) , at FAC mode menu, select Factory -> Picture -> Colour Temp item
- Set color temperature to “Standard”.
- Adjust the R Gain, G_Gain, B_Gain values to meet “Standard” color coordinates specification below. Then store those values to NVM.
- Set color temperature to “Warm”.
- Adjust the R Gain, G_Gain, B_Gain values to meet “Warm” color coordinates specification below. Then store those values to NVM.
- Set color temperature to “Cold”.
- Adjust the R Gain, G_Gain, B_Gain values to meet “Cold” color coordinates specification below. Then store those values to NVM.
- Use Minolta CA-110 for color coordinates and luminance check.
- Luminance > 400 cd/m2 in the center of the screen when Brightness control at 100; Contrast control at 100
- Reset AV setting, smart picture shall be recalled to be “Standard” and Contrast= (TBD) (CMO), Brightness=(TBD) (CMO).
PC MODE DISPLAY ADJUSTMENT
- Equipment Requirements: Minolta CA-110 or Equivalent Color analyzer Chroma 2250 or equivalent PC signal generator.
- Input requirements: Input Signal Type: PC VGA signal 1024X768/60Hz PC mode with PGCWRGB pattern. Input Signal Strength: 0.7 Vp-p linear voltage. Input Injection Point: PC D-SUB input.
ALIGNMENT METHOD
- Select source as “VGA”.
- Set Contrast = 50 (CMO) and Brightness=50 (CMO) , at Standard menu mode.
- Apply “PGCWRGB”(pattern-1) pattern by VGA pattern generator.
- Enter factory mode menu: press “MENU+ “234” then enter FAC mode
- At FAC mode menu, select FACTORY->Picture ->ADC -> Auto Colour item.
- Then press “>” key to adjust ADC_GAIN_R, ADC_GAIN_G, ADC_GAIN_B and ADC_OFFSET_R, ADC_OFFSET_G, ADC_OFFSET_B.
- Then store those values to NVM.