REQUIREMENTS
The FY*
series models enable you to update software through the serial interface.
Hardware
requirements:
One serial cable with female end and
female end;
One
PC set.
Install Gprobe 5.0:
- The first: Double click the GProbe5[1].0.0.15_S0006-EXE-09A to install it.
- According to the prompt of Windows and follow the steps one by one to finish the installation.
- The second: Double click the GPorbe5[1].0.0.15Update1_S0006-EXE-10A to install it.
According to the prompt of Windows
and follow the steps one by one to finish the installation.
- Copy the full directory of Isp_fastflash to anywhere. E.g. take the root directory of C:\ as an example for the following explanation:
- Copy the updating file *.hex to the directory of C:\ Isp_fastflash\. E.g. C:\ Isp_fastflash\20Y25.hex.
- Open C:\ Isp_fastflash\Isp_parallel\ bat.txt as follows:
- Properly set the path of RAMWrite "C:\isp_fastflash\Isp_parallel\TEMP_OBJECT\isptemp_ parallel.hex" and FastFlashWrite "C:\isp_fastflash\20y25.hex", save them and close.
- Set the LCD to off. Connect the Y# updating board and PC with parallel cable.
- Connect the VGA MONITOR interface on the Y# updating board with the VGA cable, connect the other end to the VGA interface of the LCD.
- Turn on the LCD: Double click to run Gprobe5.
- Click the icon.
- Set the Device to Parallel.
- Then click the item of Delays and Buffer Size:
- Set Long to 50000 ms.
- Click the item of Parallel:
- Set Clock to 120000 Hz.
- Click 'batch'
- The following screen appears when the process if finished.
- If you want to update the software next time, you just need to click the pull-down menu to select the desired Batch file and execute it in the following screen.
Note: Do not cut off the power or
turn off the unit during the burning process, or the flash may be damaged.
Check the following if you fail to
update:
- Check whether all cables are properly connected. If LCD is turn on.
- Check the settings of Gprobe.
- It is wrong if the Gprobe shows as the following icon.