Sunday, December 30, 2012

LG 42PT350R _ 42PT351R _ 42PT350R-TD_42PT351R-TC_SOFTWARE PROGRAM DOWNLOAD







S/W PROGRAM DOWNLOAD

  • This is for downloading the s/w to the flash memory of the IC402.
EQUIPMENT
  •  PC
  • ISP_tool program
  • Download jig
CONNECTION DIAGREAM

CONNECTION CONDITION
  1. IC name and circuit number : Flash Memory and IC402
  2. Use voltage : 3.3V (5 pin)
  3. SCL : 15 pin
  4. SDA : 12 pin
  5. Tact time : about 2 min and 30 seconds.
DOWNLOAD METHOD
  • Download method (PCB Ass’y) – HD
  • Connect the download jig to D-Sub Jack.
  • Connect the PC to USB jack.
  • Execute ‘ISP Tool’ program in PC, then a main window will be opened.
  • Click the connect button and confirm “Dialog Box”.



  • Click the Config button and Change speed E2PROM Device setting : over the 350Khz.
  • Read and write bin file
  • Click “(1)Read” tab, and then load download file(XXXX.bin) by clicking “Read”.
  • Click “Auto(2)” tab and set as below
  • Click “Run(3)”.
  • After downloading, check “OK(4)” message.