LG 42PT350R _ 42PT351R _ 42PT350R-TD_42PT351R-TC_SOFTWARE PROGRAM DOWNLOAD
S/W PROGRAM DOWNLOAD
- This is for
downloading the s/w to the flash memory of the IC402.
EQUIPMENT
- PC
- ISP_tool program
- Download jig
CONNECTION DIAGREAM
CONNECTION CONDITION
- IC name and
circuit number : Flash Memory and IC402
- Use voltage :
3.3V (5 pin)
- SCL : 15 pin
- SDA : 12 pin
- Tact time : about 2 min and 30 seconds.
DOWNLOAD METHOD
- Download method
(PCB Ass’y) – HD
- Connect the download jig to D-Sub Jack.
- Connect the PC to USB jack.
- Execute ‘ISP
Tool’ program in PC, then a main window will be opened.
- Click the connect button and confirm “Dialog
Box”.
- Click the Config
button and Change speed E2PROM Device setting : over the 350Khz.
- Read and write
bin file
- Click “(1)Read”
tab, and then load download file(XXXX.bin) by clicking “Read”.
- Click “Auto(2)”
tab and set as below
- Click “Run(3)”.
- After
downloading, check “OK(4)” message.