SELF DIAGNOSIS

  • The Self-Diagnostic circuit is a program of the Main uCom IC on the A board. This program monitors seven general faults that result in one or more of the following:
  • TV shutdown (AC relay is turned off); TV Latched OFF, (AC relay is held off); or A dark picture (no RGB signal).

As an indication of failure, the Main uCom blinks the Standby LED a number of times, pauses, then repeat.

OSD DIAGNOSTICS

  • In addition to the blinking Standby LED, the Main uCom records the number of times the failure occurred. This is useful when the user complains of an intermittent shutdown.
ACCESS DIAGNOSTIC MODE

  • To enter the test screen, first press these remote control buttons one at a time: Display, 5, Vol ( — ), Power On.
  • The screen will list the circuit monitored and the number of times the failure has occurred.

Clear the OSD Diagnostic numbers 
  • To clear the number of failures from the test screen Press 8, Enter.
STANDBY LED BLINKING CODES AND TEST POINTS

Stby LED blinks
Symptom
bd
Monitored circuit
Test point
Normal voltage

0x
Shutdown
D
+200V OCP [HV]

Q8009/C
0.1Vdc
2x
Shutdown
D
+135V OCP
CN6506/pin-8
0V
3x
Shutdown
A
Unreg 7v OVP

D6017/C
0v
3x
Shutdown
D
+135v OVP
CN6506/pin-7
0.1v
4x
Shutdown
D
V-out loss
CN5505/pin-7
0.78v
5x
Blanking
C/A/G2 adj
IK balance
CN202/pin-8
3 pulses in vertical interval

6x
Shutdown
A
Set 5v OCP
IC6007/output
5.0vdc
7x
Shutdown
D
H out OCP
CN5505/pin-8
0v