TO ENTER SERVICE MODE
Note: After replacing the IC202 (Memory) or Main CBA, the
set value in IC202 (Memory) will be lost. So it is necessary to set up or
adjust in the Service mode after its replacement.
- Turn the power on. (Use main power on the TV unit.)
- Press [STANDBY/ON], [2], [7], [1], and [MUTE] buttons on the remote control unit in that order within 5 seconds.
- To cancel the Service mode, press [STANDBY/ ON] button on the remote control.
OPTION CODE SETTING
- Enter the Service mode.
- Press the [STATUS] button on the remote control unit. The option code appears on the display.
- If needed, input the option code (0128) using number buttons on the remote control unit.
- To reset the software, press [PAUSE] and [5] buttons on the remote control unit.
- The option code is changed.
MECHANICAL TROUBLE INDICATOR
If the MONITOR is turned ON right after the Mechanical
Malfunction occurs or POWER SAFETY/ X-RAY is turned ON, display the following
character to show Malfunction after the EJECT display.
Immediately preceding Malfunction
|
Display character
|
REEL
MALFUNCTION
|
R
|
DRUM
MALFUNCTION
|
D
|
CASETTE
LOADING MALFUNCTION
|
C
|
TAPE
LOADING MALFUNCTION
|
T
|
P-SAFETY
1
|
1
|
P-SAFETY
2
|
2
|
X-RAY
|
X
|
COUNTERMEASURE FOR MECHANICAL MALFUNCTION
- If the unit detects Mechanical Malfunction, turn the POWER OFF. If the unit is Mechanical Malfunction, Key input except POWER key shall be disabled and CASSETTE insertion disabled. When POWER Key is entered, the POWER is turned ON and the unit switches over the EJECT Mode. (Return with POWER ON).