DISASSEMBLE PROCEDURE
Click on image.
Right click on the enlarged image, save image as, to a folder (My
document > My Pictures). View it in ‘Picasa’ picture viewer. There you can enlarge it more. Download ‘Picasa-3’ by Google site, and
install it to your system. It’s a free software from Google and download it by
Google. [Search for ‘Picasa’ by Google]
ADJUSTMENTS [FIRMWARE UPDATE]
TOOLS NEEDED
- Windows EDID V1.0 User Manual
- Operating System: MS Windows 98, 2000, XP
- Port Setup: Windows 98 => Don’t need setup Windows 2000,
- XP => Need to Port Setup.
- This program is available to LCD Monitor only.
PORT SETUP
- Remove all default number d)
- Add 300-3FF
- Click Start button. f)
- Click Exit button.
EDID READ AND WRITE
- Edit Week of Manufacture, Year of Manufacture, Serial Number
- Input User Info Data
- Click “Update” button
- Click “ Write” button
SERVICE OSD
- Turn off the power switch at the front side of the display.
- Wait for about 5 seconds and press MENU, POWER switch with 1 second interval.
- The SVC OSD menu contains additional menus that the User OSD menu as described below.
- Auto Color : W/B balance and Automatically sets the gain and offset value.
- NVRAM INIT : EEPROM initialize.(24C04)
- CLEAR ETI : To initialize using time.
- AGING : Select Aging mode(on/off).
- R/G/B-9300K : Allows you to set the R/G/B-9300K value manually.
- R/G/B-6500K : Allows you to set the R/G/B-6500K value manually.
- R/G/B-Offset : Allows you to set the R/G/B-Offset value manually.(Analog Only)
- R/G/B-Gain : Allows you to set the R/G/B-Gain value manually.(Analog Only)
- MODULE : Show Current module Type
- RS232: Enable/Disable Debug Mode(on/off)
WIRING DIAGRAM
EXPLODED VIEW