TO ENTER SERVICE MODE [FACTORY MODE]
{ Press "Source", "--", "CC", "SAP"} keys on the remote control in sequence to enter Service Mode [Factory Mode].
ADC CALIBRATION
- Input "SMPTE" test pattern from generator to TV component Port. {Component-1 of 2 is OK}
- Set TV to Factory Mode. Use Cursor on the remote control to move to "ADC Calibration" setting.
- Press "OK" on the remote control.
ADC - VGA CALIBRATION
- Input 16 Gray Scale pattern from the pattern generator to TV VGA Port.
- Set the TV to Factory Mode. Use cursor on the remote to move to "ADC Calibration" setting.
- Press 'OK' button on the remote control.
OPTICAL ALIGNMENT
- Plug the power cord into the socket behind TV.
- Switch ON power and press keypad Power Button to ignite lamp. Check if the Lamp is ON.
- Enter 'Factory Mode'.
- Press 'OK' to enter 'Optical Alignment' color bar image. Slope / Shape / Trapezoid to go to the permit area. {Default value: md5020/5820: left, right 25 Up, bottom: 16 md5880/6580: left, right: 37 up,bottom: 20}
- Move and rotate engine module, adjust the center line to frame.
- If the image is too high, adjust front I type screw clockwise rotation, the the screen will be moved to the lower side. If the picture is too low, adjust I type screw to counter clockwise the unit in order to move the picture higher.
- Use ratch wrench locking front two fixed studs.
- Revolve the TV, use ratch wrench locking back tow fixed studs. Attention: When locking , can't damage the wire.
- Revolve TV again , use glue machine to drop location to two I type screw.