TO ENTER SERVICE MODE
- Reduce the value of Brightness & Contrast to [0] (Zero).
- Within "5" seconds, press the "EXIT" key.
- The Service function OSD will be displayed.
- The service function OSD is based on a grid of 29 columns X 12 rows.
- The service function OSD consists of panel information, software version and MICOM checksum.
TO CONTROL SERVICE FUNCTION OSD
With the panel selected on OSD, whenever the 'right' key is pressed, the base color will change to Blue from"Panel" to ""Upper Lamp", "Lower Lamp".
After change the panel lamp, must reset the service function OSD.
- The case of panel change.
- After changing the panel, press 'Menu" key within '5' seconds.
- Then the panel Ch. No increases one step and the panel time information is reset to zero.
- Simultaneously, other information is reset to zero [Upper/Lower lamp, Panel cycle].
TO CONTROL SERVICE FUNCTION OSD
In the case of Upper Lamp or Lower Lamp change.
- Select the 'Upper Lamp" or 'Lower Lamp".
- Press 'Menu" key within '5' seconds.
- Then the Ch No and time will be reset to zero (Selected item only).