- The LEDs on the front panel do now work when connecting the power cord.
- The SMPS relay does now work, when connecting power cord.
- The unit appears to be dead.
The IP relay of the LEDs on the front panel does not work when connecting the power cord if the cables are improperly connected or the Main Board is not functioning. In this case, check:
- Check the internal cable connection status inside the unit.
- Check the fuses of each part.
- Check the output voltage of SMPS.
- Replace the Main Board.
Lamp [backlight] Off, Power indicator LED On?
|
No
|
Change power cable.
LC350_26, 32”: BN39-01278A
|
Yes
|
||
Does proper Stand-by DC A5V appear at TP-A5V?
|
No
|
Change Main Power ass’y.
LC350_26: [BN44-00368A].
LC350_32: [BN41-00369A].
|
Yes
|
||
Does proper Main DC B12V, B13V, B5V?
|
No
|
Change Main Power ass’y.
|
Yes
|
||
Does proper DC A3.3V appear at TV-A3,3V?
|
No
|
Change the Main ass’y.
LC350_26, 32: [BN94-02649A].
|
Yes
|
||
Change the LVDS cable. 26”: [BN96-12469B], 32”:
[BN96-12469C]
LOCATION - MAIN -TOP
LOCATION - MAIN - BOTTOM
|
No
|
Check Video.
|