SELF DIAGNOSTIC FUNCTION [Standby/Power LED blinking codes]
- When an error occurs, the Standby/Timer LED will flash a set number of times to indicate the possible cause of problem. If there is more than one error, the LED will identify the first of the problem areas.
- Results for all the following diagnostic items are displayed on the screen. No error occurred the screen displays a "0".
Diagnostic item
|
Lamp flashes
|
Diagnostic result
|
Probable cause location
|
Detected symptoms
|
Power does not turn on
|
Does not light
|
-----------
|
# Power cord is not plugged in. # Fuse is burned out
[F601]. {A board}
|
# Power does not come on.
# No power is supplied to the TV.
# AC power supply is faulty.
|
+B over current protection (OVP)
|
2 times
|
2:1 or 2:0
|
H.OUT [Q502] is shorted. {A board}. # IC702 is shorted {C
board}
|
# Power does not come on.
# Load on power line is shorted.
|
I-Port
|
4 times
|
4:1 or 4:0
|
# +13V is not supplied {A board}. # IC561 faulty {A board}
|
# Has entered standby state after horizontal raster.
# Vertical deflection pulse is stopped.
# Power line is shorted or power supply is stopped.
|
IK (AKB}
|
5 times
|
5:1 or 5:0
|
# IC001 is faulty {M board}. # Screen (G2) is improperly adjusted.
|
# No raster is generated.
# CRT cathode current detection reference pulse output is
small.
|
* If a +B over current is detected, stoppage of vertical deflection is detected simultaneously. The symptom that is diagnosed first by the microcomputer is displayed on the screen.
Stopping the Standby/Power LED Flash
Turn Off the Power switch on the TV main unit or unplug the power cord from the AC outlet to stop it from flashing.
DISASSEMBLY
KV-27FS320 IS PICTURED
Service Position
BOARDS
KV-27FS320 MODELS _ CABLE WIRE DRESSING
KV-32FS120 | KV-34FS120 MODELS
KV-32FS320 MODELS_ By next post.
No comments:
Post a Comment