Thursday, March 14, 2013

SONY TRINITRON KV-24LS35B - KV-24LS35E - KV-24LS35U - ERROR MESSAGES - ERROR CODES




ERRORS
Error is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous flashing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device number will be displayed through the LED (Series of flashes which must be counted).

Error Message
LED    à Code
No error  à   00
Reserved   à  01
OCP ( Over Current Protection )  à   02
Not Used  à 03
No Vertical Sync   à 04
IKR Error at power on  à 05
IIC bus clock and/or data lines low at power on à 06
NVM no IIC bus acknowledge at power on à 07
Not Used   à 08
Tuner no acknowledge at power on  à 09
Sound Processor Error à 10
Jungle controller 8 volts error à 11

ERROR COUNT
  • Turn on the main power switch of the TV set and enter into the‘Stanby Mode’.
  • Press the following sequence of buttons on the Remote Commander [ON SCREEN DISPLAY BUTTON] à [5] à [VOLUME (-Ve) à [TV].
  • The following will be displayed indicating the error count.
ERROR MENU
E02
E03
E04
E05
E06
E07
E08
E09
E10
E11

WORKING TIME
HOURS
MINUTES

OCP
OVP N/A
VSYNC
IKR
IIC
NVM
JUNGLE
TUNER
SOUNDP
8V

(0, 255)
(0, 255)
(0, 255)
(0, 255)
(0, 255)
(0, 255)
(0, 255)
(0, 255)
(0, 255)
(0, 255)

0
0
0
0
0
0
0
0
0
0


2
11
  • To clear the error count data press ‘80’ on the Remote commander.
DISASSEMBLY

  • Release the mains power cable from its securing posts.  Remove the rear cover fixing screws indicated. Pull the rear cover away from the front beznet.
Chassis Removal
  • To remove lift the main bracket rear slightly and slide the chassis away from the beznet. Ensure that the interconnecting leads are released from their purse locks to prevent damage being caused.
A Board PWB Removal
  • Release the 5 securing clips located at the side and front of the chassis and slide the PWB clear of the bracket.

Service position