SOFTWARE UPDATE
{ 2 of 2 }
Open the SVC cover for upgrading.
Connect the correct cable for each software.
UOC upgrade.
- Connect the correct cable wire in P201 for UOC upgrading. [Real wire connection is the right side of P201].
- Connect jumper in P103
- Start WISP
- Select UOCIII NIF 256.
- Set the delay line time 2ms.
IIC configuration setting.
- Select 'Single master'
- Select 100Kbits/sec
- Select LPT 1.
- Press OK.
Browse file.
- Press 'Browse'
- Select the target file.
- Press 'Open'
Upgrade
- Start “Auto Execute”
- Finish.
Scaler(Sedna) upgrade
- Connect the correct cable wire in P201 for Scaler upgrading. (Real wire connection is the Left side of P201)
- Connect jumper in P103
- Start ISP Tool
- Find the “ISP_TOOL ” icon as below
- Click and execute the Tool
- Configuration Setting.
- Select “SST/ATMEL” device
- Press “Select Intel HEX File..”
- Select the target HEX file
- Press “Open.
Upgrade
- Check “Auto reload”
- Upgrade “Erase —> Program —> Verify” in sequence
- Finish.
NVM Reset(All EEPROM Data Reset)
Purpose:
- All data RESET
- If you upgrade the UOC-III part then must do NVM RESET
- Press “S6”key in SVC remote controller.
- Press “Right” direction key in SVC remote controller.
- Then TV SET is turn off & on automatically`
- Finish.
Purpose
- To make Shipping condition
- If you upgrade the UOC-III part then must do “SHIPPING” Reset
- Press “S12”key in SVC remote controller.
- Then you can see “SHIPPING OK” on the RF Mode.
- Be sure to wait until display on the screen “SHIPPING OK”
- Then turn off the TV Set
- Finish.