All ergo meters (E30, E40, E45, E60, E80 and E85) have the same electromagnetic brake construction and apart from the E30 all the electronics and wiring are identical excluding user interface
The user interface features two menus where technical information can be edited. The first one, Settings menu, is a public menu available also to the end user and accessed via normal menus under user settings.
SETTINGS MENU
Name
|
Function
|
Bike totals / Cross
trainer totals
|
Total training time and
distance on the equipment. Use 'CLEAR' to reset both
Values.
|
SW upgrade
|
Shows the user interface's
software version. See more details about updating
the user interface
software
|
Volume control
|
Set the meter's audio
signals on or off
|
Display contrast
|
Adjust display contrast
|
SERVICE MENU
- Enter Settings menu as described above.
- Hold down 'ZOOM' –button and rotate selection wheel first 5 steps (minimum) counter-clockwise and then 5 steps clockwise.
NAME
|
FUNCTION
|
Save parameters
|
|
Restore parameters
|
|
Odometer
|
Total training time and
distance on the equipment. These values can not be
Reseted
|
Calibrate brake
|
|
Edit calibration
|
UPDATING SOFTWARE
The software of the Tunturi
, E40, E45, E60, E80 and E85 can be updated via USB connection by uploading the
new software from a PC. The PC needs to be connected to the user interface with
USBcable (comes with the sales package). Before starting the update procedure
make sure you have all the
following:
A PC or laptop with USB port
USB cable
A
new software file (of *.exe type) available on PC's hard disk. Latest versions
of software and version histories are available on Tunturi extranet.
UPDATE PROCEDURE
- Connect the USB cable between the PC and user interface (must be switched on)
- Go to the Settings menu and select 'SW UPGRADE'.
- If 'READY TO BEGIN' is displayed on the user interface's screen, start the update by double-clicking the update file.
- 'ATTACH USB CABLE' means that the connection hasn't been established. Check connection and restart PC if needed.
Double-click the update file
and the dialog below appears
- Click "Start" to start upgrade process
- The update process will take a minute or less, depending on the size of update file. After the update is completed, the user interface is automatically reseted and the start-up can take up to 30 seconds. Do not switch off the product during the recovery.
- After update verify that the new software version is in use by checking the software version number from Settings – SW Upgrade menu.
UPDATING THE E-80 & E-85 WITH A USB STICK
The Tunturi E80 and E85
software can also be updated from a USB Flash memory stick. The software update
file must be in the root of the flash drive (i.e. not in a folder).
To update the software
proceed as follows:
- Place the USB stick to either of the slots on the back of the console
- Go to the Settings menu and select 'SOFTWARE UPGRADE'.
- Choose ‘USB Flash Drive’
- Choose correct software update file to start update process
NOTE! Do not rename the update files.