PROTECT MODE: SYMPTOM;
- After once shining, it does not discharge minutely from module.
- The Rely falls.(The sound is audible “click”)
- It is converted with the color where the front LED is red from green.
TROUBLESHOOTING
Is the Power Board normal ?
|
Yes
|
Is output the
normality Low/High
voltage except Stand-by 5V?
|
No
|
Replace power baord
|
||
Yes
|
||||||
Is the each
connector
normal?
|
No
|
After
connecting well each connector,
the normality it operates?
|
Yes
|
Replace connector.
|
||
Yes
|
||||||
Is the Y-Board
normal?
|
No
|
Is the fuse(FS201) on Y-B/D
normal?(In case of open is replace)
|
Yes
|
Is the output
voltage
normal after
remove P209 connector of
Y-B/D?
|
Yes
|
Replace
Y-Board.
|
Yes
|
||||||
Is the Z-Board
normal?
|
No
|
Is the Fuse
(FS1) on Z-B/D normal?
(In case of open is
replace)
|
Yes
|
Is the output
voltage
normal after
remove
P3 connector of ZB/D?
|
Yes
|
Replace
Z-Board.
|
Yes
|
||||||
Is the X- Board normal?
|
No
|
Is the output
voltage normal after remove P242
connector of
X-B/D?
|
Yes
|
After remove
P211 output voltage normality:
Replace Right
X-B/D
After remove
P23 output voltage normality:
Replace Left X-B/D
|
||
Yes
|
||||||
Is the Ctrl Board normal?
|
No
|
Is the output voltage normal after remove P163 connector of Ctrl-B/D?
|
Yes
|
Replace the Ctrl-Board.
|
||
Yes
|
||||||
Is the VSC Board normal?
|
No
|
Is the output voltage normal after remove P1001 of VSC
Board?
|
Yes
|
After remove
P1001 normal operation:
Replace VSC Board.
|
||
Yes
|
||||||
Is the COF of
X, Y, Z
normal ?
|
No
|
After crisis
COF of each board, check the normality operates.
If in case normality operates, correspondence COF Fail is
replace the module.
|