Wednesday, July 11, 2012

MARANTZ - CD 6002 - SERVICE HELP


SERVICE MODE

  1. Insert Mains Cable plug in the outlet and press Power button.
  2. Press the Open/Close button to open the tray.
  3. While tray opened, press [>> / >>|] button for more than 5 seconds.
  4. The version number of the microprocessor will be displayed. Eg: 2007-06-25-1
  5. Press [|<< \ <<] button for more than 5 seconds.
  6. Light up all the FL segments.
  7. Turn OFF power to quit the service mode.
TAKING THE DISC OUT OF EMERGENCY
  1. Remove the top cover of the player.
  2. Remove 2 screws under the label [Yellow].
  3. Remove the disc clamper.
  4. Take out the disc, and reset all.
UPDATE MICROPROCESSOR SOFTWARE
  1. Put the 'Flash Programmer' and 'software folder' into anywhere on your PCs hard disc.
  2. Double click the 'Flash Programmer Folder'.
  3. Double click FlashProg.exe, and launch the Flash Programmer.
  4. Click 'OK'.
  5. Click the 'Setup' in the Menu Bar, and select the "object file".
  6. Click 'Browse'.
  7. Choose [Motorola S Format (*.s16,*.s24, *.s32)] in files of type.  Choose the CD6002_yymmdd_x.s24, and click open.
  8. Click 'Device tab'.
  9. Choose the TMP91FW60  in the device, and choose the 900/L1 in the series and click communication tab.
  10. Choose the Serial Port number in the Com port.  Check the data rate manual, and choose 38400 in the Data Rate.
  11. Click 'OK'.
  12. Disconnect the mains cord from the unit.
  13. Connect RS-232C on the connection jig and the Serial Port of Windows PC with RS-232C cable.
  14. Connect FFC (upside contact) to the rear panel of the unit from connection jig.
  15. Connect the Mains Cord into the unit.
  16. If the connection with the Flash Programmer is successfully made, a dialogue box saying "Erase all data in this device? (Y/N)" appears automatically.  If the connection fails, error message will appear.  Click 'Yes'.
  17. Click 'OK'.
  18. Click P [program] to start update.
  19. The software is written into the microprocessor.  It will take about 50 seconds to complete.
  20. If the software is updated successfully, a dialogue box saying, "Programming completed successfully" appears.
  21. Click 'OK'.
  22. Click the 'File' in the Menu bar, and select "Exit".
  23. Disconnect the mains cord from the unit, then disconnect FFC of connection JIG from the unit.

No comments: